Key Features
- Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements
- Outer Jacket Material: PVC - Polyvinyl Chloride
- Outer Jacket Nom. Thickness: 0.095 in (2.4 mm)
- Outer Jacket Nom. Diameter: 1.049 in (26.64 mm)
- Outer Jacket Ripcord: Yes
- Electricals Element: Conductor(s)
- Electricals Nom. Conductor DCR: 0.379 Ohm/1000ft (1.24 Ohm/km)
- Electricals Nom. Capacitance Cond-to-Cond: 33 pF/ft (110 pF/m)
Belden 29540 0103500 is an orderable item number in the Belden 29540 family (Cable › VFD Cable). Belden 300% Ground Flexible VFD, 3 Conductor 6AWG (7x19x27) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield w/3-12AWG Tinned Copper Drains, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 2000V Flexible Motor Supply Cable WTTC 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant This item: Color Black, Putup Type Reel, Length 3,500 ft, UPC 612825138488. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.505 Revision Date: 02-20-2026 |
This Item
| UPC | 612825138488 |
| Color | Black |
| Length | 3,500 ft |
| Putup Type | Reel |
| Item Number | 29540 0103500 |
Information
| Put-Up Type | Reel |
| Update And Revision | Revision Number: 0.505 Revision Date: 02-20-2026 |
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements |
Construction Details
| Conductor Row 1 — Size | 6 AWG |
| Conductor Row 2 — Size | 6 AWG |
| Outer Jacket — Ripcord | Yes |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor Row 1 — Element | Conductor(s) |
| Conductor Row 2 — Element | Ground |
| Conductor Row 1 — Material | TC - Tinned Copper |
| Conductor Row 2 — Material | TC - Tinned Copper |
| Insulation Row 1 — Element | Conductor(s) |
| Insulation Row 2 — Element | Ground |
| Conductor Row 1 — Stranding | 7x19x27 |
| Conductor Row 2 — Stranding | 7x19x27 |
| Insulation Row 1 — Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Insulation Row 2 — Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Outer Jacket — Nom. Diameter | 1.049 in (26.64 mm) |
| Insulation Row 1 — Color Code | Black and Numbered |
| Insulation Row 2 — Color Code | Green/Yellow Stripe |
| Outer Jacket — Nom. Thickness | 0.095 in (2.4 mm) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield Row 2 — Coverage | 85% |
| Outer Shield Row 2 — Material | Tinned Copper (TC) |
| Overall Cable Diameter (Nominal) | 1.049 in (26.64 mm) |
| Outer Shield Row 1 — Shield Type | Tape |
| Outer Shield Row 2 — Shield Type | Braid |
| Conductor Row 1 — No. Of Elements | 3 |
| Conductor Row 2 — No. Of Elements | 1 |
| Insulation Row 1 — Nom. Thickness | 0.072 in (1.8 mm) |
| Insulation Row 2 — Nom. Thickness | 0.072 in (1.8 mm) |
Standards And Compliance
| AWM Compliance | I/II A/B |
| Sustainability | CA Prop 65 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| ICEA Compliance | S-95-658 |
| NEC / UL Compliance | Article 336, TC-ER, WTTC, RHW-2, UL Flexible Motor Supply Cable |
| CEC / C(UL) Compliance | CIC, TC. |
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial |
| Other Standard Compliance(s) | P-07-KA070003-MSHA |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL1685 UL Loading, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU) |
Electrical Characteristics
| Electricals — Element | Conductor(s) |
| Electricals — Max. Current | 75 Amps per Conductor at 30oC |
| Voltage — UL Voltage Rating | 2000 V (TC, C(UL) TC), 1000 V (WTTC, UL Flexible Motor Supply Cable, CSA AWM I/II A/B) |
| Electricals — Nom. Inductance | 0.171 μH/ft (0.561 μH/m) |
| Electricals — Nom. Conductor DCR | 0.379 Ohm/1000ft (1.24 Ohm/km) |
| Electricals — Nom. Velocity Of Prop. | 55% |
| Electricals — Nom. Capacitance Cond-to-Cond | 33 pF/ft (110 pF/m) |
| Electricals — Nom. Characteristic Impedence | 56 Ohm |
| Electricals — Nom. Capacitance Cond-to-Other (Conds + Shield) | 60 pF/ft (200 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 785 lbs/1000ft (1170 kg/km) |
| Max. Pull Tension | 1358 lbs (616.0 kg) |
| Temperature — Operating | -40°C To +90°C |
| Temperature — UL Temperature | 90°C Dry, 90°C Wet |
| Bend Radius — Stationary Min. | 12.6 in (320 mm) |
| Bend Radius — Installation Min. | 12.6 in (320 mm) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing