Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29534 0101500.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems
- Outer Jacket Material: PVC - Polyvinyl Chloride
- Outer Jacket Nom. Thickness: 0.110 in (2.79 mm)
- Outer Jacket Nom. Diameter: 2.133 in (54.18 mm)
- Outer Jacket Ripcord: Yes
- Voltage UL Voltage Rating: 2000 V (TC, UL44)
- Voltage Voltage Rating: 1000 V (CSA TC)
- Temperature UL Temperature: 90°C Dry, 90°C Wet
Belden 29534 0101500 is an orderable item number in the Belden 29534 family (Cable › VFD Cable). Belden Basics VFD, 3 Conductor 350MCM (37x.0973") Bare Copper XLPE Insulation M4 Color Code + 2AWG Symmetrical Segmented Ground (3 of 6AWG) Bare Copper Stranded in Continuous Contact with Overall Copper Tape Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA 22.2 No. 230 TC SUN RES DIR BUR Oil Resistant This item: Color Black, Putup Type Reel, Length 1,500 m, UPC 612825138358. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.673 Revision Date: 04-01-2026 |
This Item
| UPC | 612825138358 |
| Color | Black |
| Length | 1,500 m |
| Putup Type | Reel |
| Item Number | 29534 0101500 |
Information
| Put-Up Type | Reel |
| Update And Revision | Revision Number: 0.673 Revision Date: 04-01-2026 |
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems |
Construction Details
| Conductor Row 1 — Size | 350 MCM |
| Conductor Row 2 — Size | 6 AWG |
| Outer Jacket — Ripcord | Yes |
| Conductor Row 2 — Notes | Segmented Grounds |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor Row 1 — Element | Conductor(s) |
| Conductor Row 2 — Element | Ground Wire |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | BC - Bare Copper |
| Insulation Row 1 — Element | Conductor(s) |
| Insulation Row 2 — Element | Ground Wire |
| Conductor Row 1 — Stranding | 37x0.0973 in. |
| Conductor Row 2 — Stranding | 7x14 |
| Insulation Row 1 — Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Insulation Row 2 — Material | No Insulation |
| Outer Jacket — Nom. Diameter | 2.133 in (54.18 mm) |
| Insulation Row 1 — Color Code | ICEA Method 4 |
| Outer Jacket — Nom. Thickness | 0.110 in (2.79 mm) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bare Copper (BC) |
| Outer Shield Row 2 — Material | Bare Copper (BC) |
| Overall Cable Diameter (Nominal) | 2.133 in (54.18 mm) |
| Outer Shield Row 1 — Shield Type | Helical Tape |
| Conductor Row 1 — No. Of Elements | 3 |
| Conductor Row 2 — No. Of Elements | 3 |
| Insulation Row 1 — Nom. Thickness | 0.105 in (2.67 mm) |
| Insulation Row 1 — Nom. Insulation Diameter | 0.821 in (20.9 mm) |
Standards And Compliance
| Sustainability | CA Prop 65 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| ICEA Compliance | S-95-658 |
| NEC / UL Compliance | Article 336, TC-ER, RHW-2 |
| CEC / C(UL) Compliance | CSA TC. |
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL 1685 UL Loading, IEEE 1202 FT4, FT4 |
Electrical Characteristics
| Nom Outer Shield DCR | 1.35 Ohm/1000ft (4.43 Ohm/km) |
| Voltage — Voltage Rating | 1000 V (CSA TC) |
| Electricals Row 1 — Element | Conductor(s) |
| Voltage — UL Voltage Rating | 2000 V (TC, UL44) |
| Electricals Row 1 — Max. Current | 350 Amps per Conductor at 30oC (per NEC) |
| Electricals Row 1 — Nom. Inductance | 0.136 μH/ft (0.446 μH/m) |
| Electricals Row 1 — Nom. Conductor DCR | 0.029 Ohm/1000ft (0.095 Ohm/km) |
| Electricals Row 2 — Nom. Conductor DCR | 0.43 Ohm/1000ft (1.4 Ohm/km) |
| Electricals Row 1 — Nom. Velocity Of Prop. | 55% |
| Electricals Row 1 — Nom. Capacitance Cond-to-Cond | 21 pF/ft (69 pF/m) |
| Electricals Row 1 — Nom. Characteristic Impedence | 90 Ohm |
| Electricals Row 1 — Nom. Capacitance Cond-to-Other (Conds + Shield) | 38 pF/ft (120 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 4736 lbs/1000ft (7048 kg/km) |
| Max. Pull Tension | 1910 lbs (866 kg) |
| Temperature — Operating | -40°C To +90°C |
| Temperature — UL Temperature | 90°C Dry, 90°C Wet |
| Bend Radius — Stationary Min. | 25.6 in (650 mm) |
| Bend Radius — Installation Min. | 25.6 in (650 mm) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing