Belden Store
Belden 29532T 0101500 — VFD 100% Gnd, 3C #4/0 Str TC XLPE Ins + #4/0 Symm. Seg. Grd (3 of #2) Str BC, CTS, Blk LSZH Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC

Belden Cable

Belden|

MPN: 29532T 0101500

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29532T 0101500.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; Human safety applications with flame or toxicity concerns (low smoke, zero halogen)
  • Outer Jacket Material: LSZH - Low Smoke Zero Halogen (Flame Retardant)
  • Outer Jacket Nom. Thickness: 0.085 in (2.2 mm)
  • Outer Jacket Nom. Diameter: 1.656 in (42.06 mm)
  • Outer Jacket Ripcord: Yes
  • Electricals Element: Conductor(s)
  • Electricals Nom. Conductor DCR: 0.048 Ohm/1000ft (0.16 Ohm/km)
  • Electricals Nom. Capacitance Cond-to-Cond: 54 pF/ft (180 pF/m)
Belden 29532T 0101500 is an orderable item number in the Belden 29532T family (Cable › VFD Cable). Belden 100% Ground Flexible VFD, 3 Conductor 4/0AWG (7x19x18) Tinned Copper XLPE Insulation M4 Color Code + 4/0AWG Symmetrically Segmented Ground (3 of 2AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black LSZH Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC SUN RES DIR BUR Oil Resistant This item: Color Black, Putup Type Reel, UPC 612825138303. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.267 Revision Date: 02-20-2026

This Item

UPC612825138303
ColorBlack
Putup TypeReel
Item Number29532T 0101500

Information

Put-Up TypeReel
Update And RevisionRevision Number: 0.267 Revision Date: 02-20-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Human safety applications with flame or toxicity concerns (low smoke, zero halogen)

Construction Details

Conductor Row 1 — Size4/0 AWG
Conductor Row 2 — Size2 AWG
Outer Jacket — RipcordYes
Conductor Row 2 — NotesSegmented Grounds
Outer Jacket — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Conductor Row 1 — ElementConductor(s)
Conductor Row 2 — ElementGround
Conductor Row 1 — MaterialTC - Tinned Copper
Conductor Row 2 — MaterialBC - Bare Copper
Insulation Row 1 — ElementConductor(s)
Insulation Row 2 — ElementGround
Conductor Row 1 — Stranding7x19x18
Conductor Row 2 — Stranding7x19x23
Insulation Row 1 — MaterialXLPE - Cross-Linked Polyethylene (Thermoset)
Insulation Row 2 — MaterialNo Insulation
Outer Jacket — Nom. Diameter1.656 in (42.06 mm)
Insulation Row 1 — Color CodeBlack and Numbered
Outer Jacket — Nom. Thickness0.085 in (2.2 mm)
Outer Shield Row 1 — Coverage100%
Outer Shield Row 1 — MaterialBare Copper (BC)
Outer Shield Row 2 — Coverage100%
Outer Shield Row 2 — MaterialBare Copper (BC)
Overall Cable Diameter (Nominal)1.656 in (42.06 mm)
Outer Shield Row 1 — Shield TypeHelical Tape
Outer Shield Row 2 — Shield TypeHelical Tape
Conductor Row 1 — No. Of Elements3
Conductor Row 2 — No. Of Elements3
Insulation Row 1 — Nom. Thickness0.057 in (1.4 mm)

Standards And Compliance

SustainabilityCA Prop 65
APAC ComplianceChina RoHS II (GB/T 26572-2011)
ICEA ComplianceS-95-658
NEC / UL ComplianceArticle 336, TC-ER, WTTC, UL Flexible Motor Supply Cable
Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
Flammability / Reaction To FireUL1685 FT4 Loading

Electrical Characteristics

Electricals — ElementConductor(s)
Electricals — Max. Current260 Amps per Conductor at 30oC
Voltage — UL Voltage Rating1000 V (TC, WTTC, UL Flexible Motor Supply Cable)
Electricals — Nom. Conductor DCR0.048 Ohm/1000ft (0.16 Ohm/km)
Electricals — Nom. Velocity Of Prop.55%
Electricals — Nom. Capacitance Cond-to-Cond54 pF/ft (180 pF/m)
Electricals — Nom. Characteristic Impedence44 Ohm
Electricals — Nom. Capacitance Cond-to-Other (Conds + Shield)97 pF/ft (320 pF/m)

Mechanical Characteristics

Bulk Cable Weight3183 lbs/1000ft (4737 kg/km)
Max. Pull Tension10294 lbs (4669.3 kg)
Temperature — Operating-25°C To +90°C
Temperature — UL Temperature90°C Dry, 90°C Wet
Bend Radius — Stationary Min.19.9 in (505 mm)
Bend Radius — Installation Min.19.9 in (505 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account