Belden Store
Belden 29528 0103000 — VFD 100% Gnd, 3C #1 Str TC XLPE Ins + #1 Symm. Seg. Gnd (3 of #6) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC

Belden Cable

Belden|

MPN: 29528 0103000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29528 0103000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC125A1271RA
  • Outer Jacket Material: PVC - Polyvinyl Chloride
  • Outer Jacket Nom. Thickness: 0.083 in (2.1 mm)
  • Outer Jacket Nom. Diameter: 1.195 in (30.35 mm)
  • Outer Jacket Ripcord: Yes
  • Voltage UL Voltage Rating: 1000 V (TC, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC)
  • Temperature UL Temperature: 90°C Dry, 90°C Wet
  • Temperature Operating: -40°C To +90°C
Belden 29528 0103000 is an orderable item number in the Belden 29528 family (Cable › VFD Cable). Belden 100% Ground Flexible VFD, 3 Conductor 1AWG (7x19x22) Tinned Copper XLPE Insulation M4 Color Code + 1AWG Symmetrical Segmented Ground (3 of 6AWG) Bare Copper Stranded in Continuous Contact with Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC 1000V CSA AWM I/II A/B 600V RW90 TC SUN RES DIR BUR Oil Resistant This item: Color Black, Putup Type Reel, Length 3,000 ft, UPC 612825137863, Footnote C Z. Ships from and sold by A5 IT. Quoted to order.

History

FootnoteC - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Update And RevisionRevision Number: 0.725 Revision Date: 06-30-2026

This Item

UPC612825137863
ColorBlack
Length3,000 ft
FootnoteC Z
Putup TypeReel
Item Number29528 0103000

Information

FootnoteC - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Put-Up TypeReel
Update And RevisionRevision Number: 0.725 Revision Date: 06-30-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC125A1271RA

Construction Details

Conductor Row 1 — Size1 AWG
Conductor Row 2 — Size6 AWG
Outer Jacket — RipcordYes
Conductor Row 2 — NotesSegmented Grounds (3 Totaling 1 AWG)
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor Row 1 — ElementConductor(s)
Conductor Row 2 — ElementSegmented Ground Wire
Conductor Row 1 — MaterialTC - Tinned Copper
Conductor Row 2 — MaterialBC - Bare Copper
Insulation Row 1 — ElementConductor(s)
Insulation Row 2 — ElementGround Wire
Outer Shield Row 1 — Notes2 mil Helical Copper Tape for Crack Resistance and High Frequency Noise Conduction
Outer Shield Row 2 — Notes2 mil Helical Copper Tape for Crack Resistance and High Frequency Noise Conduction
Conductor Row 1 — Stranding7x19x22
Conductor Row 2 — Stranding7x19x27
Insulation Row 1 — MaterialXLPE - Cross-Linked Polyethylene (Thermoset)
Insulation Row 2 — MaterialNo Insulation
Outer Jacket — Nom. Diameter1.195 in (30.35 mm)
Insulation Row 1 — Color CodeICEA Chart M4
Outer Jacket — Nom. Thickness0.083 in (2.1 mm)
Outer Shield Row 1 — Coverage100%
Outer Shield Row 1 — MaterialBare Copper (BC)
Outer Shield Row 2 — Coverage100%
Outer Shield Row 2 — MaterialBare Copper (BC)
Overall Cable Diameter (Nominal)1.195 in (30.35 mm)
Outer Shield Row 1 — Shield TypeHelical Tape
Outer Shield Row 2 — Shield TypeHelical Tape
Conductor Row 1 — No. Of Elements3
Conductor Row 2 — No. Of Elements3
Insulation Row 1 — Nom. Thickness0.057 in (1.4 mm)
Insulation Row 1 — Nom. Insulation Diameter0.472 in (12.0 mm)

Standards And Compliance

SustainabilityCA Prop 65
APAC ComplianceChina RoHS II (GB/T 26572-2011)
ICEA ComplianceS-95-658
NEC / UL ComplianceArticle 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable
CEC / C(UL) ComplianceTC.
Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Other Standard Compliance(s)P-07-KA070003-MSHA
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL 1685 FT4 Loading, FT4, IEEE 1202 FT4

Electrical Characteristics

Nom Outer Shield DCR0.0536 Ohm/1000ft (0.176 Ohm/km)
Electricals Row 1 — ElementConductor(s)
Electricals Row 2 — ElementSegmented Ground Wire
Voltage — UL Voltage Rating1000 V (TC, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC)
Electricals Row 1 — Max. Current145 Amps per Conductor at 30oC
Electricals Row 1 — Nom. Conductor DCR0.118 Ohm/1000ft (0.387 Ohm/km)
Electricals Row 2 — Nom. Conductor DCR0.128 Ohm/1000ft (0.420 Ohm/km)
Electricals Row 1 — Nom. Velocity Of Prop.55%
Electricals Row 1 — Nom. Inductance Cond-Grnd0.087 μH/ft
Electricals Row 1 — Nom. Capacitance Cond-to-Cond34 pF/ft (110 pF/m)
Electricals Row 1 — Nom. Characteristic Impedence37 Ohm
Electricals Row 1 — Nom. Capacitance Cond-to-Other (Conds + Shield)61 pF/ft (200 pF/m)

Mechanical Characteristics

Bulk Cable Weight1395 lbs/1000ft (2076 kg/km)
Max. Pull Tension4304 lbs (1952 kg)
Temperature — Operating-40°C To +90°C
Temperature — UL Temperature90°C Dry, 90°C Wet
Bend Radius — Stationary Min.12.0 in (305 mm)
Bend Radius — Installation Min.14.3 in (363 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account