Belden Store
Belden 29511 0105000 — VFD 300% Gnd, 3C+G #14 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd, 1 Pr #16 Str TC XLPE IS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable

Belden Cable

Belden|

MPN: 29511 0105000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29511 0105000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations
  • Inner Shield Element: Pair(s)
  • Inner Shield Shield Type: Tape
  • Inner Shield Material: Bi-Laminate (Alum+Poly)
  • Inner Shield Coverage: 100%
  • Inner Shield Drainwire Type: 18 AWG (19x30) TC
  • Inner Shield Notes: Foil-In, Shorting fold
  • Outer Jacket Material: PVC - Polyvinyl Chloride
Belden 29511 0105000 is an orderable item number in the Belden 29511 family (Cable › VFD Cable). Belden 300% Ground Flexible VFD, 3 Conductor 14AWG (41x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield, 1 Pair 16AWG (26x30) Tinned Copper XLPE Beldfoil, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant -- Shielded Pair is Outside the Power Group Braid Shield for Isolation This item: Color Black, Putup Type Reel, Length 5,000 ft, UPC 612825137511, Footnote C. Ships from and sold by A5 IT. Quoted to order.

History

FootnoteC - CRATE REEL PUT-UP.
Update And RevisionRevision Number: 0.722 Revision Date: 04-01-2026

This Item

UPC612825137511
ColorBlack
Length5,000 ft
FootnoteC
Putup TypeReel
Item Number29511 0105000

Information

FootnoteC - CRATE REEL PUT-UP.
Put-Up TypeReel
Update And RevisionRevision Number: 0.722 Revision Date: 04-01-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations

Construction Details

Inner Shield — NotesFoil-In, Shorting fold
Conductor Row 1 — Size14 AWG
Conductor Row 2 — Size16 AWG
Conductor Row 3 — Size14 AWG
Inner Shield — ElementPair(s)
Outer Jacket — RipcordYes
Outer Shield Table NotesFoil+braid shield on power conductors & Ground only; extra pair has own foil shield.
Conductor Row 2 — NotesUsed as control or brake pair
Inner Shield — Coverage100%
Inner Shield — MaterialBi-Laminate (Alum+Poly)
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor Row 1 — ElementConductor(s)
Conductor Row 2 — ElementPair(s)
Conductor Row 3 — ElementGround Wire
Conductor Row 1 — MaterialTC - Tinned Copper
Conductor Row 2 — MaterialTC - Tinned Copper
Conductor Row 3 — MaterialTC - Tinned Copper
Inner Shield — Shield TypeTape
Insulation Row 1 — ElementConductor(s)
Insulation Row 2 — ElementPair(s)
Insulation Row 3 — ElementGround Wire
Conductor Row 1 — Stranding41x30
Conductor Row 2 — Stranding26x30
Conductor Row 3 — Stranding41x30
Insulation Row 1 — MaterialXLPO - Crosslink Polyolefin
Insulation Row 2 — MaterialXLPO - Crosslink Polyolefin
Insulation Row 3 — MaterialPVC - Polyvinyl Chloride
Outer Jacket — Nom. Diameter0.820 in (20.8 mm)
Inner Shield — Drainwire Type18 AWG (19x30) TC
Insulation Row 1 — Color CodeICEA Chart M4
Insulation Row 2 — Color CodeBlack & White
Insulation Row 3 — Color CodeGreen/Yellow Stripe
Outer Jacket — Nom. Thickness0.075 in (1.9 mm)
Outer Shield Row 1 — Coverage100%
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — Coverage85%
Outer Shield Row 2 — MaterialTinned Copper (TC)
Overall Cable Diameter (Nominal)0.820 in (20.8 mm)
Outer Shield Row 1 — Shield TypeTape
Outer Shield Row 2 — Shield TypeBraid
Conductor Row 1 — No. Of Elements3
Conductor Row 2 — No. Of Elements1
Conductor Row 3 — No. Of Elements1
Insulation Row 1 — Nom. Thickness0.046 in (1.2 mm)
Insulation Row 2 — Nom. Thickness0.032 in (0.81 mm)
Insulation Row 3 — Nom. Thickness0.047 in (1.2 mm)
Outer Shield Row 1 — Drainwire Type14 AWG (41x30) TC
Insulation Row 1 — Nom. Insulation Diameter0.173 in (4.39 mm)
Insulation Row 2 — Nom. Insulation Diameter0.123 in (3.12 mm)
Insulation Row 3 — Nom. Insulation Diameter0.169 in (4.29 mm)

Standards And Compliance

AWM ComplianceAWM I/II A/B
SustainabilityCA Prop 65
APAC ComplianceChina RoHS II (GB/T 26572-2011)
ICEA ComplianceS-95-658
NEC / UL ComplianceArticle 336, Article 310, TC-ER, RHW-2, UL Flexible Motor Supply Cable
CEC / C(UL) ComplianceCIC, TC.
Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
Other Standard Compliance(s)P-07-KA070003-MSHA
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL 1685 UL Loading, FT4, IEEE 1202 FT4

Electrical Characteristics

Nom Outer Shield DCR1.08 Ohm/1000ft (3.54 Ohm/km)
Voltage — Voltage Rating1000 V (AWM I/II A/B)
Electricals Row 1 — ElementConductor(s)
Electricals Row 2 — ElementPair(s)
Electricals Row 3 — ElementGround
Voltage — UL Voltage Rating1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC)
Electricals Row 1 — Max. Current25 Amps per Conductor at 30oC (3 Current Carrying Conductors)
Electricals Row 2 — Max. Current18 Amps per Conductor at 30oC (per NEC)
Electricals Row 1 — Nom. Inductance0.213 μH/ft (0.699 μH/m)
Electricals Row 3 — Nom. Inductance0.213 μH/ft (0.699 μH/m)
Electricals Row 1 — Nom. Conductor DCR2.482 Ohm/1000ft (8.143 Ohm/km)
Electricals Row 2 — Nom. Conductor DCR4.0 Ohm/1000ft (13 Ohm/km)
Electricals Row 3 — Nom. Conductor DCR2.52 Ohm/1000ft (8.27 Ohm/km)
Electricals Row 2 — Nom. Inner Shield DCR4.99 Ohm/1000ft (16.4 Ohm/km)
Electricals Row 1 — Nom. Velocity Of Prop.55%
Electricals Row 1 — Nom. Capacitance Cond-to-Cond48 pF/ft (160 pF/m)
Electricals Row 1 — Nom. Characteristic Impedence37 Ohm
Electricals Row 2 — Nom. Capacitance Cond-to-Cond34 pF/ft (110 pF/m)
Electricals Row 3 — Nom. Capacitance Cond-to-Cond23 pF/ft (75 pF/m)
Electricals Row 1 — Nom. Capacitance Cond-to-Shield42 pF/ft (140 pF/m)
Electricals Row 3 — Nom. Capacitance Cond-to-Shield42 pF/ft (140 pF/m)
Electricals Row 1 — Nom. Capacitance Cond-to-Other (Conds + Shield)86 pF/ft (280 pF/m)

Mechanical Characteristics

Bulk Cable Weight275 lbs/1000ft (409 kg/km)
Max. Pull Tension441 lbs (200 kg)
Temperature — Operating-40°C To +90°C
Temperature — UL Temperature90°C Dry, 90°C Wet
Bend Radius — Stationary Min.9.8 in (250 mm)
Bend Radius — Installation Min.9.8 in (250 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account