Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 2181LP 009500.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Media, automation, light control
- Outer Shield Material: No Shield
- Outer Jacket Material: PVC - Polyvinyl Chloride
- Outer Jacket Nom. Thickness: 0.017 in (0.43 mm)
- Outer Jacket Nom. Diameter: 0.256 in
- Voltage UL Voltage Rating: 300 V
- Temperature UL Temperature: 60°C
- Temperature Operating: 0°C to +60°C
Belden 2181LP 009500 is an orderable item number in the Belden 2181LP family (Cable › Audio Cable › Media Automation & Lighting Systems › Lutron Systems). Lighting & Automation Cable, 2C 12 AWG 7x20 stranded, bare copper conductors unshielded, FEP insulation (power), 1C 18 AWG 7x26 stranded, bare copper conductor unshielded, FEP insulation and 1 (data) pair 22 AWG 7x30 stranded bare copper, FEP insulation, Beldfoil®shield w drain, overall Flamarrest® LS PVC jacket, CL2P rated. This item: Color White, Putup Type Reel, Length 500 ft, UPC 612825352679. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.68 Revision Date: 07-30-2026 |
This Item
| UPC | 612825352679 |
| Color | White |
| Length | 500 ft |
| Putup Type | Reel |
| Item Number | 2181LP 009500 |
Product Overview
| Suitable Applications | Media, automation, light control |
Product Life Cycle
| Life Cycle | Discontinued - the product is no longer manufactured |
| Discontinuation Announcement Date | 2019-09-10 |
Construction Details
| Conductor Row 1 — Size | 18 AWG |
| Conductor Row 2 — Size | 22 AWG |
| Conductor Row 3 — Size | 12 AWG |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield — Material | No Shield |
| Conductor Row 1 — Element | Conductor(s) |
| Conductor Row 2 — Element | Pair(s) |
| Conductor Row 3 — Element | Conductor(s) |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | BC - Bare Copper |
| Conductor Row 3 — Material | BC - Bare Copper |
| Insulation Row 1 — Element | Conductor(s) |
| Insulation Row 2 — Element | Pair(s) |
| Insulation Row 3 — Element | Conductor(s) |
| Conductor Row 1 — Stranding | 7x26 |
| Conductor Row 2 — Stranding | 7x30 |
| Conductor Row 3 — Stranding | 7x20 |
| Insulation Row 1 — Material | FEP - Fluorinated Ethylene Propylene |
| Insulation Row 2 — Material | FEP - Fluorinated Ethylene Propylene |
| Insulation Row 3 — Material | FEP - Fluorinated Ethylene Propylene |
| Outer Jacket — Nom. Diameter | 0.256 in |
| Inner Shield Row 2 — Coverage | 100% |
| Inner Shield Row 2 — Material | Bi-Laminate (Alum+Poly) |
| Insulation Row 1 — Color Code | Orange, Violet & White, Black & Red |
| Insulation Row 2 — Color Code | Violet, White |
| Insulation Row 3 — Color Code | Red, Black |
| Outer Jacket — Nom. Thickness | 0.017 in (0.43 mm) |
| Overall Cable Diameter (Nominal) | 0.256 in |
| Inner Shield Row 1 — Shield Type | No Shield |
| Inner Shield Row 2 — Shield Type | Tape |
| Inner Shield Row 3 — Shield Type | No Shield |
| Conductor Row 1 — No. Of Elements | 1 |
| Conductor Row 2 — No. Of Elements | 1 |
| Conductor Row 3 — No. Of Elements | 2 |
| Insulation Row 1 — Nom. Thickness | 0.009 in (0.23 mm) |
| Insulation Row 2 — Nom. Thickness | 0.011 in (0.28 mm) |
| Insulation Row 3 — Nom. Thickness | 0.011 in (0.28 mm) |
| Inner Shield Row 2 — Drainwire Type | 24 AWG (7x32) TC |
| Insulation Row 1 — Nom. Insulation Diameter | 0.064 in (1.6 mm) |
| Insulation Row 2 — Nom. Insulation Diameter | 0.051 in (1.3 mm) |
| Insulation Row 3 — Nom. Insulation Diameter | 0.111 in (2.82 mm) |
Standards And Compliance
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum Number | 2181LA |
| NEC / UL Compliance | Article 725, CL2P |
| CEC / C(UL) Compliance | CL2P. |
| Environmental Suitability | Indoor - Plenum, Indoor |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | NFPA 262 (UL910), FT6 |
Electrical Characteristics
| Electricals Row 1 — Element | Conductor(s) |
| Electricals Row 2 — Element | Pair(s) |
| Electricals Row 3 — Element | Conductor(s) |
| Voltage — UL Voltage Rating | 300 V |
| Electricals Row 1 — Max. Current | 4 Amps per Conductor |
| Electricals Row 2 — Max. Current | 2.2 Amps per Conductor at 25oC |
| Electricals Row 3 — Max. Current | 9.6 Amps per Conductor |
| Electricals Row 1 — Nom. Conductor DCR | 6.5 Ohm/1000ft |
| Electricals Row 2 — Nom. Conductor DCR | 17.9 Ohm/1000ft (58.7 Ohm/km) |
| Electricals Row 3 — Nom. Conductor DCR | 1.6 Ohm/1000ft (5.2 Ohm/km) |
| Electricals Row 2 — Nom. Inner Shield DCR | 17.4 Ohm/1000ft (57.1 Ohm/km) |
| Electricals Row 2 — Nom. Capacitance Cond-to-Cond | 25 pF/ft (82 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 70 lbs/1000ft |
| Max. Pull Tension | 220 lbs (100 kg) |
| Temperature — Operating | 0°C to +60°C |
| Temperature — UL Temperature | 60°C |
| Bend Radius — Stationary Min. | 2.56 in (65.0 mm) |
| Bend Radius — Installation Min. | 2.56 in |
Purchasing this for your business?