Key Features

  • Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.
  • Conductor Element: Pair(s)
  • Conductor AWG: 16
  • Conductor Stranding: 7x24
  • Conductor Material: TC - Tinned Copper
  • Insulation Element: Conductor(s)
  • Insulation Material: XLPE - Cross-Linked Polyethylene (Thermoset)
  • Color Chart Number: 1
Belden 2109A 0035000 is an orderable item number in the Belden 2109A family (Cable › Electronic Wire & Cable › Multi-Pair Cable). Fieldbus, 1 Pair 16AWG (7x24H) Tinned Copper, XLPO Insulation, Overall Beldfoil® Shield, TPE Outer Jacket, CMG This item: Color Orange, Put-Up Type Reel, Length 5,000 ft, UPC 612825129165. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.662 Revision Date: 06-10-2026

Standards

NEC ArticlesArticle 725, Article 800
CSA AWM ComplianceAWM I A/B II A/B, C22.2 #230 Type TC; C22.2#239 Type CIC
NEC/(UL) ComplianceCMG, ITC, PLTC

This Item

UPC612825129165
ColorOrange
Length5,000 ft
Item Number2109A 0035000
Put-Up TypeReel

Suitability

Suitability - BurialYes
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Oil ResistanceYes
Suitability - Sunlight ResistanceYes

Product Overview

Suitable Applicationsharsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

UL Temperature Rating90°C Wet/Dry
Installation Temp Rating-25°C
Operating Temperature Range-25°C Cold Impact -40°C to +90°C -55°C Cold Bend

Electrical Characteristics

Current — ElementPer Conductor
Voltage — DescriptionCSA CIC type TC
Voltage — UL Voltage Rating300 V
Voltage — Voltage Rating [V]300 V RMS
Electrical Characteristics NotesMax Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft
Inductance — Nominal Inductance0.22 μH/ft
Other Electrical Characteristic 231.25 KBits/sec
Conductor DCR — Nominal Conductor DCR4.52 Ohm/1000ft
Current — Max. Recommended Current [A]6.1 Amps per Conductor
Capacitance — Max. Capacitance Unbalance1.2 pF/ft
Impedance — Nominal Characteristic Impedance120 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]64%
Capacitance — Nom. Capacitance Conductor To Shield22 pF/ft
High Frequency — Max. Insertion Loss (Attenuation)0.091 dB/100ft
High Frequency — Max./Min. Input Impedance (UnFitted)100 Ohm
High Frequency (Nominal/Typical) — Nom. Insertion Loss0.065 dB/100ft

Mechanical Characteristics

UV ResistanceYes
Oil ResistanceYes
Bulk Cable Weight67 lbs/1000ft
Minimum Minor Axis Bend Radius3.75 in
Maximum Recommended Pulling Tension71.4 lbs
Minimum Bend Radius During Installation3.65 in

Physical Characteristics (Overall)

Conductor Count2
Conductor — AWG16
Color Chart — ColorBlue, Orange and Numbered
Conductor — ElementPair(s)
Outer Shield — TypeTape
Total Number Of Pairs1
Color Chart — Number1
Conductor — MaterialTC - Tinned Copper
Insulation — ElementConductor(s)
Conductor — Stranding7x24
Insulation — MaterialXLPE - Cross-Linked Polyethylene (Thermoset)
Outer Jacket — RipcordYes
Outer Jacket — MaterialTPE - Thermoplastic Elastomer
Outer Shield — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 1 — TypeTape
Inner Shield Row 1 — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 2 — MaterialTinned Copper (TC)
Outer Jacket — Nominal Diameter0.365 in
Inner Shield Row 1 — Coverage [%]100%
Inner Shield Row 1 — Drainwire AWG18
Outer Jacket — Nominal Wall Thickness0.047 in
Inner Shield Row 1 — Material Trade NameBeldfoil®
Inner Shield Row 1 — Drainwire Construction N X D7x26

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 FT4 Loading
IEC FlammabilityIEC 60332-3-24
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account