Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 2109A 0035000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.
- Conductor Element: Pair(s)
- Conductor AWG: 16
- Conductor Stranding: 7x24
- Conductor Material: TC - Tinned Copper
- Insulation Element: Conductor(s)
- Insulation Material: XLPE - Cross-Linked Polyethylene (Thermoset)
- Color Chart Number: 1
Belden 2109A 0035000 is an orderable item number in the Belden 2109A family (Cable › Electronic Wire & Cable › Multi-Pair Cable). Fieldbus, 1 Pair 16AWG (7x24H) Tinned Copper, XLPO Insulation, Overall Beldfoil® Shield, TPE Outer Jacket, CMG This item: Color Orange, Put-Up Type Reel, Length 5,000 ft, UPC 612825129165. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.662 Revision Date: 06-10-2026 |
Standards
| NEC Articles | Article 725, Article 800 |
| CSA AWM Compliance | AWM I A/B II A/B, C22.2 #230 Type TC; C22.2#239 Type CIC |
| NEC/(UL) Compliance | CMG, ITC, PLTC |
This Item
| UPC | 612825129165 |
| Color | Orange |
| Length | 5,000 ft |
| Item Number | 2109A 0035000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Burial | Yes |
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Oil Resistance | Yes |
| Suitability - Sunlight Resistance | Yes |
Product Overview
| Suitable Applications | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| UL Temperature Rating | 90°C Wet/Dry |
| Installation Temp Rating | -25°C |
| Operating Temperature Range | -25°C Cold Impact -40°C to +90°C -55°C Cold Bend |
Electrical Characteristics
| Current — Element | Per Conductor |
| Voltage — Description | CSA CIC type TC |
| Voltage — UL Voltage Rating | 300 V |
| Voltage — Voltage Rating [V] | 300 V RMS |
| Electrical Characteristics Notes | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
| Inductance — Nominal Inductance | 0.22 μH/ft |
| Other Electrical Characteristic 2 | 31.25 KBits/sec |
| Conductor DCR — Nominal Conductor DCR | 4.52 Ohm/1000ft |
| Current — Max. Recommended Current [A] | 6.1 Amps per Conductor |
| Capacitance — Max. Capacitance Unbalance | 1.2 pF/ft |
| Impedance — Nominal Characteristic Impedance | 120 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 64% |
| Capacitance — Nom. Capacitance Conductor To Shield | 22 pF/ft |
| High Frequency — Max. Insertion Loss (Attenuation) | 0.091 dB/100ft |
| High Frequency — Max./Min. Input Impedance (UnFitted) | 100 Ohm |
| High Frequency (Nominal/Typical) — Nom. Insertion Loss | 0.065 dB/100ft |
Mechanical Characteristics
| UV Resistance | Yes |
| Oil Resistance | Yes |
| Bulk Cable Weight | 67 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 3.75 in |
| Maximum Recommended Pulling Tension | 71.4 lbs |
| Minimum Bend Radius During Installation | 3.65 in |
Physical Characteristics (Overall)
| Conductor Count | 2 |
| Conductor — AWG | 16 |
| Color Chart — Color | Blue, Orange and Numbered |
| Conductor — Element | Pair(s) |
| Outer Shield — Type | Tape |
| Total Number Of Pairs | 1 |
| Color Chart — Number | 1 |
| Conductor — Material | TC - Tinned Copper |
| Insulation — Element | Conductor(s) |
| Conductor — Stranding | 7x24 |
| Insulation — Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Outer Jacket — Ripcord | Yes |
| Outer Jacket — Material | TPE - Thermoplastic Elastomer |
| Outer Shield — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 1 — Type | Tape |
| Inner Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 2 — Material | Tinned Copper (TC) |
| Outer Jacket — Nominal Diameter | 0.365 in |
| Inner Shield Row 1 — Coverage [%] | 100% |
| Inner Shield Row 1 — Drainwire AWG | 18 |
| Outer Jacket — Nominal Wall Thickness | 0.047 in |
| Inner Shield Row 1 — Material Trade Name | Beldfoil® |
| Inner Shield Row 1 — Drainwire Construction N X D | 7x26 |
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 FT4 Loading |
| IEC Flammability | IEC 60332-3-24 |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing