Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 2100A 0035000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.
- Conductor Element: Pair(s)
- Conductor AWG: 18
- Conductor Stranding: 7x26
- Conductor Material: TC - Tinned Copper
- Insulation Material: XLPE - Cross-Linked Polyethylene (Thermoset)
- Color Chart Number: 1
- Color Chart Color: Blue, Orange and Numbered
Belden 2100A 0035000 is an orderable item number in the Belden 2100A family (Cable › Electronic Wire & Cable › Multi-Pair Cable). Fieldbus, 1 Pair 18AWG (7x26) Tinned Copper, XLPO Insulation, Overall Beldfoil® Shield, TPE Outer Jacket, CMG This item: Color Orange, Put-Up Type Reel, Length 5,000 ft, UPC 612825128762. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.660 Revision Date: 06-10-2026 |
Standards
| NEC Articles | Article 725, Article 727, Article 800 |
| CSA AWM Compliance | AWM I A/B II A/B, C22.2 #230 Type TC; C22.2#239 Type CIC |
| NEC/(UL) Compliance | CMG, ITC, PLTC |
| CEC/C(UL) Compliance | CIC, TC |
This Item
| UPC | 612825128762 |
| Color | Orange |
| Length | 5,000 ft |
| Item Number | 2100A 0035000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Oil Resistance | Yes |
| Suitability - Sunlight Resistance | Yes |
Product Overview
| Suitable Applications | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| UL Temperature Rating | 90°C Wet/Dry |
| Installation Temp Rating | -25°C |
| Operating Temperature Range | -25°C Cold Impact -40°C to +90°C -55°C Cold Bend |
| Installation Temperature Range | -25°C |
Electrical Characteristics
| Current — Element | Per Conductor |
| Voltage — Description | CSA CIC type TC |
| Voltage — UL Voltage Rating | 300 V |
| Voltage — Voltage Rating [V] | 300 V RMS |
| Electrical Characteristics Notes | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
| Inductance — Nominal Inductance | 0.22 μH/ft |
| Other Electrical Characteristic 2 | 31.25 KBits/sec |
| Conductor DCR — Nominal Conductor DCR | 5.86 Ohm/1000ft |
| Current — Max. Recommended Current [A] | 8.7 Amps per Conductor |
| Capacitance — Max. Capacitance Unbalance | 1.2 pF/ft |
| Impedance — Nominal Characteristic Impedance | 100 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 64% |
| High Frequency — Max. Insertion Loss (Attenuation) | 0.091 dB/100ft |
| Capacitance — Nom. Capacitance Conductor To Conductor | 22 pF/ft |
| High Frequency — Max./Min. Input Impedance (UnFitted) | 100 Ohm |
| High Frequency (Nominal/Typical) — Nom. Insertion Loss | 0.08 dB/100ft |
Mechanical Characteristics
| UV Resistance | Yes |
| Bulk Cable Weight | 51 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 3.25 in |
| Maximum Recommended Pulling Tension | 57 lbs |
Physical Characteristics (Overall)
| Conductor Count | 2 |
| Conductor — AWG | 18 |
| Color Chart — Color | Blue, Orange and Numbered |
| Conductor — Element | Pair(s) |
| Total Number Of Pairs | 1 |
| Color Chart — Number | 1 |
| Conductor — Material | TC - Tinned Copper |
| Conductor — Stranding | 7x26 |
| Insulation — Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Outer Jacket — Ripcord | Yes |
| Outer Jacket — Material | TPE - Thermoplastic Elastomer |
| Inner Shield Row 1 — Type | Tape |
| Inner Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 2 — Material | Tinned Copper (TC) |
| Outer Jacket — Nominal Diameter | 0.319 in |
| Inner Shield Row 1 — Coverage [%] | 100% |
| Inner Shield Row 1 — Drainwire AWG | 20 |
| Inner Shield Row 1 — Material Trade Name | Beldfoil® |
| Inner Shield Row 1 — Drainwire Construction N X D | 7x28 |
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 FT4 Loading |
| IEC Flammability | IEC 60332-3-24 |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |