Key Features

  • Suitable Applications: Work area patch cable; Support current and future Category 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T, 10 Base - T, FDDI, ATM
  • Conductor Element: Individual Pair
  • Conductor Size: 26 AWG
  • Conductor Stranding: 7x34
  • Conductor Material: BC - Bare Copper
  • Conductor No. of Pairs: 4
  • Insulation Element: Individual Pair
  • Insulation Material: PE - Polyethylene
Belden 1868E.01500 is an orderable item number in the Belden 1868E family (Cable › Ethernet Cable › Category 5e Cable). Category 5e Patch Cable (100MHz), 4-Pair, 26 AWG stranded (7x34) bare copper conductors, F/UTP, Polyethylene insulation, Beldfoil® shield, AWG 26 stranded (7x34) tinned copper drainwire, PVC jacket This item: Color Blue, Putup Type Reel, Length 500 m, EAN 8719605004536. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.289 Revision Date: 02-20-2026

This Item

EAN8719605004536
ColorBlue
Length500 m
Putup TypeReel
Item Number1868E.01500

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system.

Product Overview

Suitable ApplicationsWork area patch cable; Support current and future Category 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T, 10 Base - T, FDDI, ATM

Construction Details

Conductor — Size26 AWG
Conductor — ElementIndividual Pair
Conductor — MaterialBC - Bare Copper
Insulation — ElementIndividual Pair
Conductor — Stranding7x34
Insulation — MaterialPE - Polyethylene
Outer Shield Table NotesAluminum facing inside in contact with drain wire
Insulation — Color CodeBlack/Blue & Blue, Black/Orange & Orange, Black/Green & Green, Black/Brown & Brown
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — Coverage100%
Outer Shield — MaterialBi-Laminate (Alum+Poly)
Cable Core — Description4 pairs twisted together
Conductor — No. Of Pairs4
Outer Shield — Shield TypeTape
Outer Jacket — Nom. Diameter5.4 mm (0.21 in)
Outer Shield — Drainwire Type26 AWG (7x34) TC
Overall Cable Diameter (Nominal)5.4 mm (0.21 in)
Insulation — Nom. Insulation Diameter0.95 mm (0.037 in)

Standards And Compliance

Data CategoryCategory 5e
IEEE CompliancePoE: IEEE 802.3bt Type 1, Type 2, Type 3
CENELEC ComplianceEN 50173-1, Segregation class according EN50174-2 = a
ISO/IEC ComplianceISO/IEC 11801-1
TIA/EIA ComplianceANSI/TIA 568.2-D
UK Regulation ComplianceUKCA Mark
Environmental SuitabilityIndoor
European Directive ComplianceEU CE Mark
Flammability / Reaction To FireIEC 60332-1-2

Electrical Characteristics

Screening ClassType II
Screening Table NotesCoupling Attenuation
Transfer Impedance ClassGrade 2
Delay — Max. Delay Skew40 ns/100m
High Frequency Table NotesLimits below 4 MHz are for information only. Reference standard: IEC 61156-5
Voltage — Voltage Rating72 V DC
Delay — Nom. Velocity Of Prop.60%
Electricals — Max. Conductor DCR145 Ohm/km (44.2 Ohm/1000ft)
High Frequency Row 1 — Min. ACR [DB]62.1
High Frequency Row 1 — Min. TCL [DB]40
High Frequency Row 2 — Min. ACR [DB]50.3
High Frequency Row 2 — Min. TCL [DB]34
High Frequency Row 3 — Min. ACR [DB]40.8
High Frequency Row 3 — Min. TCL [DB]30
High Frequency Row 4 — Min. ACR [DB]35.2
High Frequency Row 4 — Min. TCL [DB]28
High Frequency Row 5 — Min. ACR [DB]32.2
High Frequency Row 5 — Min. TCL [DB]27
High Frequency Row 6 — Min. ACR [DB]25.8
High Frequency Row 6 — Min. TCL [DB]25.1
High Frequency Row 7 — Min. ACR [DB]13.6
High Frequency Row 7 — Min. TCL [DB]22
High Frequency Row 8 — Min. ACR [DB]3.3
High Frequency Row 8 — Min. TCL [DB]20
Transfer Impedance Row 1 — Frequency1 Mhz
Transfer Impedance Row 2 — Frequency10 Mhz
Transfer Impedance Row 3 — Frequency30 Mhz
Transfer Impedance Row 4 — Frequency100 Mhz
Electricals — Max. Mutual Capacitance56 pF/m (17 pF/ft)
High Frequency Row 1 — Min. NEXT [DB]65.3
High Frequency Row 2 — Min. NEXT [DB]56.3
High Frequency Row 3 — Min. NEXT [DB]50.3
High Frequency Row 4 — Min. NEXT [DB]47.2
High Frequency Row 5 — Min. NEXT [DB]45.8
High Frequency Row 6 — Min. NEXT [DB]42.9
High Frequency Row 7 — Min. NEXT [DB]38.4
High Frequency Row 8 — Min. NEXT [DB]35.3
High Frequency Row 1 — Frequency [MHz]1
High Frequency Row 1 — Min. PSACR [DB]59.1
High Frequency Row 2 — Frequency [MHz]4
High Frequency Row 2 — Min. PSACR [DB]47.3
High Frequency Row 3 — Frequency [MHz]10
High Frequency Row 3 — Min. PSACR [DB]37.8
High Frequency Row 4 — Frequency [MHz]16
High Frequency Row 4 — Min. PSACR [DB]32.2
High Frequency Row 5 — Frequency [MHz]20
High Frequency Row 5 — Min. PSACR [DB]29.2
High Frequency Row 6 — Frequency [MHz]31.25
High Frequency Row 6 — Min. PSACR [DB]22.8
High Frequency Row 7 — Frequency [MHz]62.5
High Frequency Row 7 — Min. PSACR [DB]10.6
High Frequency Row 8 — Frequency [MHz]100
High Frequency Row 8 — Min. PSACR [DB]0.3
High Frequency Row 1 — Min. ELTCTL [DB]35
High Frequency Row 1 — Min. PSNEXT [DB]62.3
High Frequency Row 2 — Min. ELTCTL [DB]23
High Frequency Row 2 — Min. PSNEXT [DB]53.3
High Frequency Row 3 — Min. ELTCTL [DB]15
High Frequency Row 3 — Min. PSNEXT [DB]47.3
High Frequency Row 4 — Min. ELTCTL [DB]10.9
High Frequency Row 4 — Min. PSNEXT [DB]44.2
High Frequency Row 5 — Min. ELTCTL [DB]9
High Frequency Row 5 — Min. PSNEXT [DB]42.8
High Frequency Row 6 — Min. ELTCTL [DB]5.5
High Frequency Row 6 — Min. PSNEXT [DB]39.9
High Frequency Row 7 — Min. PSNEXT [DB]35.4
High Frequency Row 8 — Min. PSNEXT [DB]32.3
Electricals — Max. Capacitance Unbalance160 pF/100m
Electricals — Nom. Characteristic Impedance100 Ohm
High Frequency Row 1 — Min. ACRF (ELFEXT) [DB]64
High Frequency Row 2 — Min. ACRF (ELFEXT) [DB]52
High Frequency Row 3 — Min. ACRF (ELFEXT) [DB]44
High Frequency Row 4 — Min. ACRF (ELFEXT) [DB]39.9
High Frequency Row 5 — Min. ACRF (ELFEXT) [DB]38
High Frequency Row 6 — Min. ACRF (ELFEXT) [DB]34.1
High Frequency Row 7 — Min. ACRF (ELFEXT) [DB]28.1
High Frequency Row 8 — Min. ACRF (ELFEXT) [DB]24
High Frequency Row 1 — Min. RL (Return Loss) [DB]20
High Frequency Row 2 — Min. RL (Return Loss) [DB]23
High Frequency Row 3 — Min. RL (Return Loss) [DB]25
High Frequency Row 4 — Min. RL (Return Loss) [DB]25
High Frequency Row 5 — Min. RL (Return Loss) [DB]25
High Frequency Row 6 — Min. RL (Return Loss) [DB]23.3
High Frequency Row 7 — Min. RL (Return Loss) [DB]20.7
High Frequency Row 8 — Min. RL (Return Loss) [DB]19
High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB]61
High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB]49
High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB]41
High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB]36.9
High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB]35
High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB]31.5
High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB]25.1
High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB]21
Transfer Impedance Row 1 — Max. Transfer ImpedanceMax. 50 mOhm/m
Transfer Impedance Row 2 — Max. Transfer ImpedanceMax. 100 mOhm/m
Transfer Impedance Row 3 — Max. Transfer ImpedanceMax. 200 mOhm/m
Transfer Impedance Row 4 — Max. Transfer ImpedanceMax. 1000 mOhm/m
High Frequency Row 1 — Max. Insertion Loss (Attenuation)3.2 dB/100m
High Frequency Row 2 — Max. Insertion Loss (Attenuation)6 dB/100m
High Frequency Row 3 — Max. Insertion Loss (Attenuation)9.5 dB/100m
High Frequency Row 4 — Max. Insertion Loss (Attenuation)12.1 dB/100m
High Frequency Row 5 — Max. Insertion Loss (Attenuation)13.5 dB/100m
High Frequency Row 6 — Max. Insertion Loss (Attenuation)17.1 dB/100m
High Frequency Row 7 — Max. Insertion Loss (Attenuation)24.8 dB/100m
High Frequency Row 8 — Max. Insertion Loss (Attenuation)32 dB/100m

Mechanical Characteristics

Bulk Cable Weight31 kg/km
Max. Pull Tension45 N (10 lbf)
Temperature — Operating-30°C to +60°C
Temperature — Installation0°C To +50°C
Bend Radius — Stationary Min.21 mm (0.83 in)
Bend Radius — Installation Min.42 mm

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account