Belden Store
Belden 1852F Z4B500 — Audio Snake Cable, #24-24pr, TC, Indiv. Shielded, CMG

Belden Cable

Belden|

MPN: 1852F Z4B500

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1852F Z4B500.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Multi-channel interconnect between audio equipment such as microphones, speakers, amplifiers, mixing consoles; Live events or studio sound; Analog audio
  • Conductor Size: 24
  • Conductor Stranding: 7x32
  • Conductor Material: TC - Tinned Copper
  • Conductor No. of Pairs: 24
  • Inner Shield Shield Type: Tape
  • Inner Shield Material: Bi-Laminate (Alum+Poly)
  • Inner Shield Coverage: 100%
Belden 1852F Z4B500 is an orderable item number in the Belden 1852F family (Cable › Audio Cable › Digital Audio Cable). Digital Audio Snake Cable, CMG-Rated, 24-24 AWG tinned copper pairs, Datalene® insulation, individually shielded with Beldfoil, numbered/color-coded PVC jackets, flexible PVC jacket This item: Color Violet Z4B, Putup Type Reel, Length 500 ft, UPC 612825124467, Footnote C. Ships from and sold by A5 IT. Quoted to order.

History

FootnoteC - CRATE REEL PUT-UP.
Update And RevisionRevision Number: 0.354 Revision Date: 07-30-2026

This Item

UPC612825124467
ColorViolet Z4B
Length500 ft
FootnoteC
Putup TypeReel
Item Number1852F Z4B500

Product Notes

NotesPair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight.

Product Overview

Suitable ApplicationsMulti-channel interconnect between audio equipment such as microphones, speakers, amplifiers, mixing consoles; Live events or studio sound; Analog audio

Product Life Cycle

Life CycleDiscontinued - the product is no longer manufactured
Discontinuation Announcement Date2023-02-21

Construction Details

Conductor — Size24
Conductor — MaterialTC - Tinned Copper
Conductor — Stranding7x32
Inner Shield Table NotesIndiv. Foil tapes bonded to inner jacket
Outer Jacket — RipcordYes
Inner Jacket — MaterialPVC - Polyvinyl Chloride
Inner Shield — Coverage100%
Inner Shield — MaterialBi-Laminate (Alum+Poly)
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — Coverage100%
Outer Shield — MaterialBi-Laminate (Alum+Poly)
Conductor — No. Of Pairs24
Insulation Row 1 — NotesHDPE
Inner Shield — Shield TypeTape
Outer Shield — Shield TypeTape
Insulation Row 1 — MaterialPE - Polyethylene (Foam)
Inner Jacket — Nom. Diameter0.167 in (4.24 mm)
Outer Jacket — Nom. Diameter1.21 in
Insulation Row 1 — Color CodeBrown and Numbered 1, Red and Numbered 2, Orange and Numbered 3, Yellow and Numbered 4, Green and Numbered 5, Blue and Numbered 6, Purple and Numbered 7, Gray and Numbered 8, White and Numbered 9, Black and Numbered 10, Tan and Numbered 11, Pink and Numbered 12, Gray/Brown Stripe and Numbered 13, Gray/Red Stripe and Numbered 14, Gray/Orange Stripe and Numbered 15, Gray/Yellow Stripe and Numbered 16, Gray/Green Stripe and Numbered 17, Gray/Blue Stripe and Numbered 18, Gray/Purple Stripe and Numbered 19, Gray/Gray Stripe and Numbered 20, Gray/White Stripe and Numbered 21, Gray/Black Stripe and Numbered 22, Gray/Tan Stripe and Numbered 23, Gray/Pink Stripe and Numbered 24
Insulation Row 2 — Color CodeRed & Black
Insulation Row 1 — Nom. Insulation Diameter0.068 in (1.7 mm)

Standards And Compliance

APAC ComplianceChina RoHS II (GB/T 26572-2011)
NEC / UL ComplianceCMG
CEC / C(UL) ComplianceCMG.
Environmental SuitabilityIndoor (Not Riser or Plenum), Indoor
Other Standard Compliance(s)AES/EBU
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL1685 FT4 Loading

Electrical Characteristics

Delay — Nom. Velocity Of Prop.76%
High Frequency Row 1 — Frequency [MHz]0.384
High Frequency Row 2 — Frequency [MHz]0.706
High Frequency Row 3 — Frequency [MHz]0.768
High Frequency Row 4 — Frequency [MHz]1.024
High Frequency Row 5 — Frequency [MHz]1.411
High Frequency Row 6 — Frequency [MHz]1.536
High Frequency Row 7 — Frequency [MHz]2.048
High Frequency Row 8 — Frequency [MHz]2.822
High Frequency Row 9 — Frequency [MHz]3.072
High Frequency Row 10 — Frequency [MHz]4.096
High Frequency Row 11 — Frequency [MHz]5.645
High Frequency Row 12 — Frequency [MHz]6.144
High Frequency Row 13 — Frequency [MHz]8.192
High Frequency Row 14 — Frequency [MHz]11.29
High Frequency Row 15 — Frequency [MHz]12.288
High Frequency Row 16 — Frequency [MHz]24.576
Electricals — Nom. Characteristic Impedance110 Ohm

Mechanical Characteristics

Bulk Cable Weight558 lbs/1000ft (830 kg/km)
Max. Pull Tension400 lbs (180 kg)
Temperature — Operating-30°C To +60°C
Temperature — UL Temperature60°C

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account