Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1674A TIN1000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Conductor AWG: 29
- Conductor Stranding: Solid
- Conductor Material: SCCS - Silvered Copper Covered Steel
- Conductor Nominal Diameter: 0.011 in
- Conductor No. of Coax: 1
- Insulation Material: PTFE - Polytetrafluoroethylene
- Insulation Material Trade Name: Teflon®
- Insulation Nominal Diameter: 0.034 in
Belden 1674A TIN1000 is an orderable item number in the Belden 1674A family (Cable › Coax & Triax Cable › 50 Ohm Coax Cable). M17/151 type, 29 AWG solid .011" silver-plated copper-covered steel conductor, TFE Teflon® insulation, copper-tin composite shield (100% coverage), unjacketed. This item: Color Tin, Put-Up Type Reel, Length 1,000 ft, UPC 612825120490. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.437 Revision Date: 02-20-2026 |
Standards
| UL AWM Style Compliance | AWM 10245 (30 V 105°C) |
This Item
| UPC | 612825120490 |
| Color | Tin |
| Length | 1,000 ft |
| Item Number | 1674A TIN1000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
Product Notes
| Notes | VSWR limit is a continuous line from 500 MHz to 20 GHz |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| Non-UL Temp Rating | 200°C |
| UL Temperature Rating | 105°C |
| Operating Temperature Range | -70°C To +200°C |
Electrical Characteristics
| Delay — Nominal Delay | 1.46 ns/ft |
| VSWR Row 1 — Max. VSWR | 1.16:1 |
| VSWR Row 2 — Max. VSWR | 1.17:1 |
| VSWR Row 3 — Max. VSWR | 1.24:1 |
| VSWR Row 4 — Max. VSWR | 1.33:1 |
| VSWR Row 5 — Max. VSWR | 1.41:1 |
| VSWR Row 6 — Max. VSWR | 1.50:1 |
| VSWR Row 7 — Max. VSWR | 1.50:1 |
| VSWR Row 8 — Max. VSWR | 1.50:1 |
| Voltage — UL Voltage Rating | 30 V RMS |
| VSWR Row 1 — Frequency [MHz] | 500 MHz |
| VSWR Row 2 — Frequency [MHz] | 1000 MHz |
| VSWR Row 3 — Frequency [MHz] | 5000 MHz |
| VSWR Row 4 — Frequency [MHz] | 10000 MHz |
| VSWR Row 5 — Frequency [MHz] | 15000 MHz |
| VSWR Row 6 — Frequency [MHz] | 20000 MHz |
| VSWR Row 7 — Frequency [MHz] | 18000 MHz |
| VSWR Row 8 — Frequency [MHz] | 20000 MHz |
| Inductance — Nominal Inductance | 0.07 μH/ft |
| Voltage — Non-UL Voltage Rating | 1000 V RMS |
| Conductor DCR — Outer Conductor DCR | 8 Ohm/1000ft |
| Power Rating Row 1 — Frequency [MHz] | 500 MHz |
| Power Rating Row 2 — Frequency [MHz] | 1,000 MHz |
| Power Rating Row 3 — Frequency [MHz] | 2,000 MHz |
| Power Rating Row 4 — Frequency [MHz] | 3,000 MHz |
| Power Rating Row 5 — Frequency [MHz] | 5,000 MHz |
| Power Rating Row 6 — Frequency [MHz] | 7,000 MHz |
| Power Rating Row 7 — Frequency [MHz] | 10,000 MHz |
| Power Rating Row 8 — Frequency [MHz] | 15,000 MHz |
| Power Rating Row 9 — Frequency [MHz] | 18,000 MHz |
| Conductor DCR — Nominal Conductor DCR | 205 Ohm/1000ft |
| Power Rating Row 10 — Frequency [MHz] | 20,000 MHz |
| Conductor DCR — Nominal Outer Shield DCR | 8 Ohm/1000ft |
| Power Rating Row 1 — Max. Power Rating [W] | 45 W |
| Power Rating Row 2 — Max. Power Rating [W] | 31 W |
| Power Rating Row 3 — Max. Power Rating [W] | 22 W |
| Power Rating Row 4 — Max. Power Rating [W] | 18 W |
| Power Rating Row 5 — Max. Power Rating [W] | 13 W |
| Power Rating Row 6 — Max. Power Rating [W] | 11 W |
| Power Rating Row 7 — Max. Power Rating [W] | 9.3 W |
| Power Rating Row 8 — Max. Power Rating [W] | 7.6 W |
| Power Rating Row 9 — Max. Power Rating [W] | 6.9 W |
| Power Rating Row 10 — Max. Power Rating [W] | 6.5 W |
| Impedance — Nominal Characteristic Impedance | 50 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 70% |
| Capacitance — Nom. Capacitance Conductor To Shield | 29.5 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 500 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 1000 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 2000 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 3000 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 5000 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 7000 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 10000 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 15000 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 18000 MHz |
| High Frequency (Nominal/Typical) Row 10 — Frequency [MHz] | 20000 MHz |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 205 Ohm/1000ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 25 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 36.7 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 53.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 67.3 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 89.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 107.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 130.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 163.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 181.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss | 192 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 3 lbs/1000ft |
| Min Flexing Radius | 0.375 in |
| Min Bend Radius (Overall) | 0.5 in |
| Maximum Recommended Pulling Tension | 20 lbs |
| Minimum Bend Radius During Installation | 0.125 in |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 29 |
| Conductor — Material | SCCS - Silvered Copper Covered Steel |
| Conductor — Stranding | Solid |
| Insulation — Material | PTFE - Polytetrafluoroethylene |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | No Jacket |
| Outer Shield Row 1 — Type | Tape |
| Outer Shield Row 2 — Type | Braid |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Conductor — Nominal Diameter | 0.011 in |
| Insulation — Nominal Diameter | 0.034 in |
| Outer Shield Row 1 — Material | Bare Copper (BC) |
| Outer Shield Row 2 — Material | Tinned Copper (TC + Tin Filled) |
| Insulation — Material Trade Name | Teflon® |
| Outer Shield Row 1 — Coverage [%] | 100% |
| Outer Shield Row 2 — Coverage [%] | 100% |
Flammability, LS0H, Toxicity Testing
| UL Flammability | Horizontal Wire |
| UL Voltage Rating | 30 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | No |
| Environmental Space | Indoor/Outdoor |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |