Key Features

  • Conductor AWG: 29
  • Conductor Stranding: Solid
  • Conductor Material: SCCS - Silvered Copper Covered Steel
  • Conductor Nominal Diameter: 0.011 in
  • Conductor No. of Coax: 1
  • Insulation Material: PTFE - Polytetrafluoroethylene
  • Insulation Material Trade Name: Teflon®
  • Insulation Nominal Diameter: 0.034 in
Belden 1674A TIN1000 is an orderable item number in the Belden 1674A family (Cable › Coax & Triax Cable › 50 Ohm Coax Cable). M17/151 type, 29 AWG solid .011" silver-plated copper-covered steel conductor, TFE Teflon® insulation, copper-tin composite shield (100% coverage), unjacketed. This item: Color Tin, Put-Up Type Reel, Length 1,000 ft, UPC 612825120490. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.437 Revision Date: 02-20-2026

Standards

UL AWM Style ComplianceAWM 10245 (30 V 105°C)

This Item

UPC612825120490
ColorTin
Length1,000 ft
Item Number1674A TIN1000
Put-Up TypeReel

Suitability

Suitability - IndoorYes
Suitability - OutdoorYes

Product Notes

NotesVSWR limit is a continuous line from 500 MHz to 20 GHz

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Non-UL Temp Rating200°C
UL Temperature Rating105°C
Operating Temperature Range-70°C To +200°C

Electrical Characteristics

Delay — Nominal Delay1.46 ns/ft
VSWR Row 1 — Max. VSWR1.16:1
VSWR Row 2 — Max. VSWR1.17:1
VSWR Row 3 — Max. VSWR1.24:1
VSWR Row 4 — Max. VSWR1.33:1
VSWR Row 5 — Max. VSWR1.41:1
VSWR Row 6 — Max. VSWR1.50:1
VSWR Row 7 — Max. VSWR1.50:1
VSWR Row 8 — Max. VSWR1.50:1
Voltage — UL Voltage Rating30 V RMS
VSWR Row 1 — Frequency [MHz]500 MHz
VSWR Row 2 — Frequency [MHz]1000 MHz
VSWR Row 3 — Frequency [MHz]5000 MHz
VSWR Row 4 — Frequency [MHz]10000 MHz
VSWR Row 5 — Frequency [MHz]15000 MHz
VSWR Row 6 — Frequency [MHz]20000 MHz
VSWR Row 7 — Frequency [MHz]18000 MHz
VSWR Row 8 — Frequency [MHz]20000 MHz
Inductance — Nominal Inductance0.07 μH/ft
Voltage — Non-UL Voltage Rating1000 V RMS
Conductor DCR — Outer Conductor DCR8 Ohm/1000ft
Power Rating Row 1 — Frequency [MHz]500 MHz
Power Rating Row 2 — Frequency [MHz]1,000 MHz
Power Rating Row 3 — Frequency [MHz]2,000 MHz
Power Rating Row 4 — Frequency [MHz]3,000 MHz
Power Rating Row 5 — Frequency [MHz]5,000 MHz
Power Rating Row 6 — Frequency [MHz]7,000 MHz
Power Rating Row 7 — Frequency [MHz]10,000 MHz
Power Rating Row 8 — Frequency [MHz]15,000 MHz
Power Rating Row 9 — Frequency [MHz]18,000 MHz
Conductor DCR — Nominal Conductor DCR205 Ohm/1000ft
Power Rating Row 10 — Frequency [MHz]20,000 MHz
Conductor DCR — Nominal Outer Shield DCR8 Ohm/1000ft
Power Rating Row 1 — Max. Power Rating [W]45 W
Power Rating Row 2 — Max. Power Rating [W]31 W
Power Rating Row 3 — Max. Power Rating [W]22 W
Power Rating Row 4 — Max. Power Rating [W]18 W
Power Rating Row 5 — Max. Power Rating [W]13 W
Power Rating Row 6 — Max. Power Rating [W]11 W
Power Rating Row 7 — Max. Power Rating [W]9.3 W
Power Rating Row 8 — Max. Power Rating [W]7.6 W
Power Rating Row 9 — Max. Power Rating [W]6.9 W
Power Rating Row 10 — Max. Power Rating [W]6.5 W
Impedance — Nominal Characteristic Impedance50 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]70%
Capacitance — Nom. Capacitance Conductor To Shield29.5 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]500 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]1000 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]2000 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]3000 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]5000 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]7000 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]10000 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]15000 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]18000 MHz
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]20000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance205 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss25 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss36.7 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss53.8 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss67.3 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss89.2 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss107.5 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss130.9 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss163.8 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss181.1 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss192 dB/100ft

Mechanical Characteristics

Bulk Cable Weight3 lbs/1000ft
Min Flexing Radius0.375 in
Min Bend Radius (Overall)0.5 in
Maximum Recommended Pulling Tension20 lbs
Minimum Bend Radius During Installation0.125 in

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG29
Conductor — MaterialSCCS - Silvered Copper Covered Steel
Conductor — StrandingSolid
Insulation — MaterialPTFE - Polytetrafluoroethylene
Conductor — No. Of Coax1
Outer Jacket — MaterialNo Jacket
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.011 in
Insulation — Nominal Diameter0.034 in
Outer Shield Row 1 — MaterialBare Copper (BC)
Outer Shield Row 2 — MaterialTinned Copper (TC + Tin Filled)
Insulation — Material Trade NameTeflon®
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]100%

Flammability, LS0H, Toxicity Testing

UL FlammabilityHorizontal Wire
UL Voltage Rating30 V RMS

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceIndoor/Outdoor
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account