Key Features
- Conductor AWG: 19
- Conductor Stranding: Solid
- Conductor Material: SCCS - Silvered Copper Covered Steel
- Conductor Nominal Diameter: 0.036 in
- Conductor No. of Coax: 1
- Insulation Material: PTFE - Polytetrafluoroethylene
- Insulation Material Trade Name: Teflon®
- Insulation Nominal Diameter: 0.116 in
Belden 1673J 010100 is an orderable item number in the Belden 1673J family (Cable › Coax & Triax Cable › 50 Ohm Coax Cable). RG-402/U type, 19 AWG solid .036" silver-plated copper-covered steel conductor, TFE Teflon® Insulation, copper-tin composite shield (100% coverage), PVC jacket. This item: Color Black, Put-Up Type Reel, Length 100 ft, UPC 612825120452. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.404 Revision Date: 02-20-2026 |
Standards
| RG Type | 402 |
| UL AWM Style Compliance | AWM 10245 |
This Item
| UPC | 612825120452 |
| Color | Black |
| Length | 100 ft |
| Item Number | 1673J 010100 |
| Put-Up Type | Reel |
Suitability
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
Product Notes
| Notes | Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc. |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| Non-UL Temp Rating | 105°C |
| UL Temperature Rating | 105°C |
| Operating Temperature Range | -40°C To +105°C |
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP., V - 250' PUT-UP EXACT LENGTH MAXIMUM OF 3 PIECES, MINIMUM LENGTH 50'. 500' PUT-UP EXACT LENGTH MAXIMUM OF 5 PIECES, MINIMUM LENGTH 50'. 1000' PUT-UP EXACT LENGTH MAXIMUM OF 8 PIECES, MINIMUM LENGTH 50'. |
Electrical Characteristics
| VSWR Row 1 — Element | Ramp Function, End Points |
| Delay — Nominal Delay | 1.46 ns/ft |
| VSWR Row 1 — Max. VSWR | 1.1 |
| VSWR Row 2 — Max. VSWR | 1.3 |
| Voltage — UL Voltage Rating | 30 V RMS |
| VSWR Row 1 — Frequency [MHz] | 500 MHz |
| VSWR Row 2 — Frequency [MHz] | 20000 MHz |
| Inductance — Nominal Inductance | 0.07 μH/ft |
| Voltage — Non-UL Voltage Rating | 1900 V RMS |
| Conductor DCR — Outer Conductor DCR | 4.5 Ohm/1000ft |
| Power Rating Row 1 — Frequency [MHz] | 500 MHz |
| Power Rating Row 2 — Frequency [MHz] | 1,000 MHz |
| Power Rating Row 3 — Frequency [MHz] | 2,000 MHz |
| Power Rating Row 4 — Frequency [MHz] | 3,000 MHz |
| Power Rating Row 5 — Frequency [MHz] | 5,000 MHz |
| Power Rating Row 6 — Frequency [MHz] | 7,000 MHz |
| Power Rating Row 7 — Frequency [MHz] | 10,000 MHz |
| Power Rating Row 8 — Frequency [MHz] | 15,000 MHz |
| Power Rating Row 9 — Frequency [MHz] | 18,000 MHz |
| Conductor DCR — Nominal Conductor DCR | 20.5 Ohm/1000ft |
| Power Rating Row 10 — Frequency [MHz] | 20,000 MHz |
| High Frequency Row 1 — Frequency [MHz] | 500 MHz |
| High Frequency Row 2 — Frequency [MHz] | 1000 MHz |
| High Frequency Row 3 — Frequency [MHz] | 3000 MHz |
| High Frequency Row 4 — Frequency [MHz] | 5000 MHz |
| High Frequency Row 5 — Frequency [MHz] | 10000 MHz |
| High Frequency Row 6 — Frequency [MHz] | 20000 MHz |
| Conductor DCR — Nominal Outer Shield DCR | 4.5 Ohm/1000ft |
| Power Rating Row 1 — Max. Power Rating [W] | 600 W |
| Power Rating Row 2 — Max. Power Rating [W] | 401 W |
| Power Rating Row 3 — Max. Power Rating [W] | 268 W |
| Power Rating Row 4 — Max. Power Rating [W] | 211 W |
| Power Rating Row 5 — Max. Power Rating [W] | 157 W |
| Power Rating Row 6 — Max. Power Rating [W] | 129 W |
| Power Rating Row 7 — Max. Power Rating [W] | 105 W |
| Power Rating Row 8 — Max. Power Rating [W] | 83 W |
| Power Rating Row 9 — Max. Power Rating [W] | 74 W |
| Power Rating Row 10 — Max. Power Rating [W] | 70 W |
| Impedance — Nominal Characteristic Impedance | 50 Ohm |
| Power Rating Row 1 — Nominal Power Rating [W] | 600 W |
| Power Rating Row 2 — Nominal Power Rating [W] | 401 W |
| Power Rating Row 3 — Nominal Power Rating [W] | 268 W |
| Power Rating Row 4 — Nominal Power Rating [W] | 211 W |
| Power Rating Row 5 — Nominal Power Rating [W] | 157 W |
| Power Rating Row 6 — Nominal Power Rating [W] | 129 W |
| Power Rating Row 7 — Nominal Power Rating [W] | 105 W |
| Power Rating Row 8 — Nominal Power Rating [W] | 83 W |
| Power Rating Row 9 — Nominal Power Rating [W] | 74 W |
| Power Rating Row 10 — Nominal Power Rating [W] | 70 W |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 70% |
| Capacitance — Nom. Capacitance Conductor To Shield | 29.5 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 500 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 1000 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 2000 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 3000 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 5000 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 7000 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 10000 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 15000 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 18000 MHz |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) | 9.5 dB/100ft |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) | 14.5 dB/100ft |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) | 26.5 dB/100ft |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) | 36 dB/100ft |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) | 54 dB/100ft |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) | 84 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Frequency [MHz] | 20000 MHz |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 20.5 Ohm/1000ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 8 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 12 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 18.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 22.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 31 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 37.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 46.6 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 59.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 65.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss | 70 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 32 lbs/1000ft |
| Min Flexing Radius | 0.75 in |
| Min Bend Radius (Overall) | 1.5 in |
| Maximum Recommended Pulling Tension | 70 lbs |
| Minimum Bend Radius During Installation | 0.25 in |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 19 |
| Conductor — Material | SCCS - Silvered Copper Covered Steel |
| Conductor — Stranding | Solid |
| Insulation — Material | PTFE - Polytetrafluoroethylene |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield Row 1 — Type | Tape |
| Outer Shield Row 2 — Type | Braid |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Conductor — Nominal Diameter | 0.036 in |
| Insulation — Nominal Diameter | 0.116 in |
| Outer Shield Row 1 — Material | Bare Copper (BC) |
| Outer Shield Row 2 — Material | Tinned Copper (TC + Tin Filled) |
| Outer Jacket — Nominal Diameter | 0.178 in |
| Insulation — Material Trade Name | Teflon® |
| Outer Shield Row 1 — Coverage [%] | 100% |
| Outer Shield Row 2 — Coverage [%] | 100% |
Flammability, LS0H, Toxicity Testing
| UL Flammability | Horizontal Wire |
| UL Voltage Rating | 30 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | No |
| Environmental Space | Indoor/Outdoor |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |