Belden Store
Belden 1673B TIN100 — 50 Ohm Microwave, RG402 Commercial Non-QPL Product, 19 AWG SPC Coax, Unjacketed

Belden Cable

Belden|

MPN: 1673B TIN100

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1673B TIN100.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Microwave
  • Conductor AWG: 19
  • Conductor Stranding: Solid
  • Conductor Material: SC - Silvered Copper
  • Conductor Nominal Diameter: 0.036 in
  • Conductor No. of Coax: 1
  • Insulation Material: PTFE - Polytetrafluoroethylene
  • Insulation Material Trade Name: Teflon®
Belden 1673B TIN100 is an orderable item number in the Belden 1673B family (Cable › Coax & Triax Cable › 50 Ohm Coax Cable). 50 Ohm, RG-402/U type commercial non-QPL product, 19 AWG solid .036" silver-plated copper conductor, PTFE insulation, copper-tin composite shield (100% coverage), unjacketed. This item: Color Tin, Put-Up Type Reel, Length 100 ft, UPC 612825120421. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.435 Revision Date: 02-20-2026

Standards

RG Type402
Qualified Products ListNo

This Item

UPC612825120421
ColorTin
Length100 ft
Item Number1673B TIN100
Put-Up TypeReel

Suitability

Suitability - AerialNo
Suitability - BurialNo
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Hazardous LocationsNo

Product Notes

NotesCommercial non-QPL product

Product Overview

Suitable ApplicationsMicrowave

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Non-UL Temp Rating200°C
Operating Temperature Range-70°C To +200°C

Related Part Numbers

FootnoteE - MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25'.

Electrical Characteristics

VSWR Row 1 — ElementRamp Function, End Points
Delay — Nominal Delay1.46 ns/ft
VSWR Row 1 — Max. VSWR1.1:1
VSWR Row 2 — Max. VSWR1.11:1
VSWR Row 3 — Max. VSWR1.13:1
VSWR Row 4 — Max. VSWR1.17:1
VSWR Row 5 — Max. VSWR1.25:1
VSWR Row 6 — Max. VSWR1.3:1
VSWR Row 1 — Frequency [MHz]500 MHz
VSWR Row 2 — Frequency [MHz]1000 MHz
VSWR Row 3 — Frequency [MHz]3000 MHz
VSWR Row 4 — Frequency [MHz]7000 MHz
VSWR Row 5 — Frequency [MHz]15000 MHz
VSWR Row 6 — Frequency [MHz]20000 MHz
Electrical Characteristics NotesVSWR limit is a continuous sloping line from 500 MHz to 20 GHz
Inductance — Nominal Inductance0.07 μH/ft
Voltage — Non-UL Voltage Rating1900 V RMS
Conductor DCR — Outer Conductor DCR4.5 Ohm/1000ft
Power Rating Row 1 — Frequency [MHz]500 MHz
Power Rating Row 2 — Frequency [MHz]1,000 MHz
Power Rating Row 3 — Frequency [MHz]2,000 MHz
Power Rating Row 4 — Frequency [MHz]3,000 MHz
Power Rating Row 5 — Frequency [MHz]5,000 MHz
Power Rating Row 6 — Frequency [MHz]7,000 MHz
Power Rating Row 7 — Frequency [MHz]10,000 MHz
Power Rating Row 8 — Frequency [MHz]15,000 MHz
Power Rating Row 9 — Frequency [MHz]18,000 MHz
Conductor DCR — Nominal Conductor DCR7.9 Ohm/1000ft
Power Rating Row 10 — Frequency [MHz]20,000 MHz
High Frequency Row 1 — Frequency [MHz]500 MHz
High Frequency Row 2 — Frequency [MHz]1000 MHz
High Frequency Row 3 — Frequency [MHz]3000 MHz
High Frequency Row 4 — Frequency [MHz]5000 MHz
High Frequency Row 5 — Frequency [MHz]10000 MHz
High Frequency Row 6 — Frequency [MHz]20000 MHz
Conductor DCR — Nominal Outer Shield DCR4.5 Ohm/1000ft
Power Rating Row 1 — Max. Power Rating [W]600 W
Power Rating Row 2 — Max. Power Rating [W]401 W
Power Rating Row 3 — Max. Power Rating [W]268 W
Power Rating Row 4 — Max. Power Rating [W]211 W
Power Rating Row 5 — Max. Power Rating [W]157 W
Power Rating Row 6 — Max. Power Rating [W]129 W
Power Rating Row 7 — Max. Power Rating [W]105 W
Power Rating Row 8 — Max. Power Rating [W]83 W
Power Rating Row 9 — Max. Power Rating [W]74 W
Power Rating Row 10 — Max. Power Rating [W]70 W
Impedance — Nominal Characteristic Impedance50 Ohm
Power Rating Row 1 — Nominal Power Rating [W]600 W
Power Rating Row 2 — Nominal Power Rating [W]401 W
Power Rating Row 3 — Nominal Power Rating [W]268 W
Power Rating Row 4 — Nominal Power Rating [W]211 W
Power Rating Row 5 — Nominal Power Rating [W]157 W
Power Rating Row 6 — Nominal Power Rating [W]129 W
Power Rating Row 7 — Nominal Power Rating [W]105 W
Power Rating Row 8 — Nominal Power Rating [W]83 W
Power Rating Row 9 — Nominal Power Rating [W]74 W
Power Rating Row 10 — Nominal Power Rating [W]70 W
Delay — Nominal Velocity Of Propagation (VP) [%]70%
Capacitance — Nom. Capacitance Conductor To Shield29.5 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]500 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]1000 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]2000 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]3000 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]5000 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]7000 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]10000 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]15000 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]18000 MHz
High Frequency Row 1 — Max. Insertion Loss (Attenuation)9.5 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)14.5 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)26.5 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)36 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)54 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)84 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]20000 MHz
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss8 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss12 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss18.1 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss22.9 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss31 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss37.8 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss46.6 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss59.1 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss65.8 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss70 dB/100ft

Mechanical Characteristics

Bulk Cable Weight25 lbs/1000ft
Min Flexing Radius0.75 in
Maximum Recommended Pulling Tension70 lbs
Minimum Bend Radius During Operation.375 in
Minimum Bend Radius During Installation0.125 in

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG19
Conductor — MaterialSC - Silvered Copper
Conductor — StrandingSolid
Insulation — MaterialPTFE - Polytetrafluoroethylene
Conductor — No. Of Coax1
Outer Jacket — MaterialNo Jacket
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.036 in
Insulation — Nominal Diameter0.116 in
Outer Shield Row 1 — MaterialBare Copper (BC)
Outer Shield Row 2 — MaterialTinned Copper (TC + Tin Filled)
Insulation — Material Trade NameTeflon®
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]100%

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceIndoor/Outdoor
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account