Belden Store
Belden 1672J 0101000 — 75 Ohm High-Frequency Conformable Coax, #29 SCCCS Coax, Unjacketed

Belden Cable

Belden|

MPN: 1672J 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1672J 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 29
  • Conductor Stranding: Solid
  • Conductor Material: SCCS - Silvered Copper Covered Steel
  • Conductor Nominal Diameter: 0.0114 in
  • Conductor No. of Coax: 1
  • Insulation Material: PTFE - Polytetrafluoroethylene
  • Insulation Material Trade Name: Teflon®
  • Insulation Nominal Diameter: 0.062 in
Belden 1672J 0101000 is an orderable item number in the Belden 1672J family (Cable › Video Cable › Coaxial Video Cable). 29 AWG solid .011" silver-coated copper-covered steel conductor, TFE Teflon® insulation, copper-tin composite shield (100% coverage), PVC jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825120360. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.399 Revision Date: 02-20-2026

Standards

RG Type405
UL AWM Style ComplianceAWM 10245

This Item

UPC612825120360
ColorBlack
Length1,000 ft
Item Number1672J 0101000
Put-Up TypeReel

Suitability

Suitability - IndoorYes
Suitability - OutdoorYes

Product Notes

NotesTeflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc.

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Non-UL Temp Rating105°C
UL Temperature Rating105°C
Operating Temperature Range-40°C To +105°C

Related Part Numbers

FootnoteV - 250' PUT-UP EXACT LENGTH MAXIMUM OF 3 PIECES, MINIMUM LENGTH 50'. 500' PUT-UP EXACT LENGTH MAXIMUM OF 5 PIECES, MINIMUM LENGTH 50'. 1000' PUT-UP EXACT LENGTH MAXIMUM OF 8 PIECES, MINIMUM LENGTH 50'., E - MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25'., C - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.46 ns/ft
Voltage — UL Voltage Rating30 V RMS
Return Loss — Frequency [MHz]10-1000 MHz
Inductance — Nominal Inductance0.109 μH/ft
Voltage — Non-UL Voltage Rating900 V RMS
Conductor DCR — Outer Conductor DCR10 Ohm/1000ft
Power Rating Row 1 — Frequency [MHz]1 MHz
Power Rating Row 2 — Frequency [MHz]10 MHz
Power Rating Row 3 — Frequency [MHz]50 MHz
Power Rating Row 4 — Frequency [MHz]100 MHz
Power Rating Row 5 — Frequency [MHz]200 MHz
Power Rating Row 6 — Frequency [MHz]400 MHz
Power Rating Row 7 — Frequency [MHz]700 MHz
Power Rating Row 8 — Frequency [MHz]1,000 MHz
Conductor DCR — Nominal Conductor DCR205 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR10 Ohm/1000ft
Power Rating Row 1 — Max. Power Rating [W]520 W
Power Rating Row 2 — Max. Power Rating [W]295 W
Power Rating Row 3 — Max. Power Rating [W]195 W
Power Rating Row 4 — Max. Power Rating [W]160 W
Power Rating Row 5 — Max. Power Rating [W]140 W
Power Rating Row 6 — Max. Power Rating [W]130 W
Power Rating Row 7 — Max. Power Rating [W]127 W
Power Rating Row 8 — Max. Power Rating [W]125 W
Impedance — Nominal Characteristic Impedance75 Ohm
Power Rating Row 1 — Nominal Power Rating [W]520 W
Power Rating Row 2 — Nominal Power Rating [W]295 W
Power Rating Row 3 — Nominal Power Rating [W]195 W
Power Rating Row 4 — Nominal Power Rating [W]160 W
Power Rating Row 5 — Nominal Power Rating [W]140 W
Power Rating Row 6 — Nominal Power Rating [W]130 W
Power Rating Row 7 — Nominal Power Rating [W]127 W
Power Rating Row 8 — Nominal Power Rating [W]125 W
Return Loss — Min. Structural Return Loss (SRL)25 dB
Delay — Nominal Velocity Of Propagation (VP) [%]70%
Capacitance — Nom. Capacitance Conductor To Shield19.5 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance205 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss1.6 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss1.8 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss4.1 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss6.5 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss9 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss12.8 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss18 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss22.1 dB/100ft

Mechanical Characteristics

Bulk Cable Weight16 lbs/1000ft
Min Flexing Radius0.375 in
Min Bend Radius (Overall)1 in
Maximum Recommended Pulling Tension20 lbs
Minimum Bend Radius During Installation0.125 in

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG29
Conductor — MaterialSCCS - Silvered Copper Covered Steel
Conductor — StrandingSolid
Insulation — MaterialPTFE - Polytetrafluoroethylene
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.0114 in
Insulation — Nominal Diameter0.062 in
Outer Shield Row 1 — MaterialBare Copper (BC)
Outer Shield Row 2 — MaterialTinned Copper (TC + Tin Filled)
Outer Jacket — Nominal Diameter0.127 in
Insulation — Material Trade NameTeflon®
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]100%

Flammability, LS0H, Toxicity Testing

UL FlammabilityHorizontal Wire
UL Voltage Rating30 V RMS

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceIndoor/Outdoor
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account