Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1671B TIN500.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Microwave
- Conductor AWG: 24
- Conductor Stranding: Solid
- Conductor Material: SC - Silvered Copper
- Conductor Nominal Diameter: 0.02 in
- Conductor No. of Coax: 1
- Insulation Material: PTFE - Polytetrafluoroethylene
- Insulation Material Trade Name: Teflon®
Belden 1671B TIN500 is an orderable item number in the Belden 1671B family (Cable › Coax & Triax Cable › 50 Ohm Coax Cable). 50 Ohm, RG-405/U type , 24 AWG solid .020" silver-plated copper conductor, PTFE insulation, copper-tin composite shield (100% coverage), unjacketed. This item: Color Tin, Put-Up Type Reel, Length 500 ft, UPC 612825120308. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.425 Revision Date: 02-20-2026 |
Standards
| RG Type | 405 |
| Qualified Products List | No |
This Item
| UPC | 612825120308 |
| Color | Tin |
| Length | 500 ft |
| Item Number | 1671B TIN500 |
| Put-Up Type | Reel |
Suitability
| Suitability - Aerial | No |
| Suitability - Burial | No |
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Hazardous Locations | No |
Product Notes
| Notes | Commercial non-QPL product |
Product Overview
| Suitable Applications | Microwave |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| Non-UL Temp Rating | 200°C |
| Operating Temperature Range | -70°C To +200°C |
Related Part Numbers
| Footnote | E - MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25'. |
Electrical Characteristics
| Delay — Nominal Delay | 1.46 ns/ft |
| VSWR Row 1 — Max. VSWR | 1.1:1 |
| VSWR Row 2 — Max. VSWR | 1.11:1 |
| VSWR Row 3 — Max. VSWR | 1.13:1 |
| VSWR Row 4 — Max. VSWR | 1.17:1 |
| VSWR Row 5 — Max. VSWR | 1.25:1 |
| VSWR Row 6 — Max. VSWR | 1.3:1 |
| Voltage — UL Voltage Rating | 30 V RMS (UL AWM Style 10245) |
| VSWR Row 1 — Frequency [MHz] | 500 MHz |
| VSWR Row 2 — Frequency [MHz] | 1000 MHz |
| VSWR Row 3 — Frequency [MHz] | 3000 MHz |
| VSWR Row 4 — Frequency [MHz] | 7000 MHz |
| VSWR Row 5 — Frequency [MHz] | 15000 MHz |
| VSWR Row 6 — Frequency [MHz] | 20000 MHz |
| Electrical Characteristics Notes | VSWR limit is a continuous sloping line from 500 MHz to 20 GHz |
| Inductance — Nominal Inductance | 0.07 μH/ft |
| Voltage — Non-UL Voltage Rating | 1500 V RMS |
| Conductor DCR — Outer Conductor DCR | 10.2 Ohm/1000ft |
| Power Rating Row 1 — Frequency [MHz] | 500 MHz |
| Power Rating Row 2 — Frequency [MHz] | 1,000 MHz |
| Power Rating Row 3 — Frequency [MHz] | 2,000 MHz |
| Power Rating Row 4 — Frequency [MHz] | 3,000 MHz |
| Power Rating Row 5 — Frequency [MHz] | 5,000 MHz |
| Power Rating Row 6 — Frequency [MHz] | 7,000 MHz |
| Power Rating Row 7 — Frequency [MHz] | 10,000 MHz |
| Power Rating Row 8 — Frequency [MHz] | 15,000 MHz |
| Power Rating Row 9 — Frequency [MHz] | 18,000 MHz |
| Conductor DCR — Nominal Conductor DCR | 25.7 Ohm/1000ft |
| Power Rating Row 10 — Frequency [MHz] | 20,000 MHz |
| High Frequency Row 1 — Frequency [MHz] | 500 MHz |
| High Frequency Row 2 — Frequency [MHz] | 1000 MHz |
| High Frequency Row 3 — Frequency [MHz] | 2000 MHz |
| High Frequency Row 4 — Frequency [MHz] | 3000 MHz |
| High Frequency Row 5 — Frequency [MHz] | 5000 MHz |
| High Frequency Row 6 — Frequency [MHz] | 7000 MHz |
| High Frequency Row 7 — Frequency [MHz] | 10000 MHz |
| High Frequency Row 8 — Frequency [MHz] | 15000 MHz |
| High Frequency Row 9 — Frequency [MHz] | 18000 MHz |
| High Frequency Row 10 — Frequency [MHz] | 20000 MHz |
| Power Rating Row 1 — Max. Power Rating [W] | 180 W |
| Power Rating Row 2 — Max. Power Rating [W] | 119 W |
| Power Rating Row 3 — Max. Power Rating [W] | 79 W |
| Power Rating Row 4 — Max. Power Rating [W] | 62 W |
| Power Rating Row 5 — Max. Power Rating [W] | 46 W |
| Power Rating Row 6 — Max. Power Rating [W] | 37 W |
| Power Rating Row 7 — Max. Power Rating [W] | 30 W |
| Power Rating Row 8 — Max. Power Rating [W] | 24 W |
| Power Rating Row 9 — Max. Power Rating [W] | 21 W |
| Power Rating Row 10 — Max. Power Rating [W] | 20 W |
| Impedance — Nominal Characteristic Impedance | 50 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 70% |
| Capacitance — Nom. Capacitance Conductor To Shield | 29.5 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 500 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 1000 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 2000 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 3000 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 5000 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 7000 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 10000 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 15000 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 18000 MHz |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) | 17 dB/100ft |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) | 24.9 dB/100ft |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) | 36.5 dB/100ft |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) | 45.7 dB/100ft |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) | 60.5 dB/100ft |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) | 72.9 dB/100ft |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) | 88.7 dB/100ft |
| High Frequency Row 8 — Max. Insertion Loss (Attenuation) | 110.9 dB/100ft |
| High Frequency Row 9 — Max. Insertion Loss (Attenuation) | 122.7 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Frequency [MHz] | 20000 MHz |
| High Frequency Row 10 — Max. Insertion Loss (Attenuation) | 130 dB/100ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 15 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 22.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 32.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 41.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 54.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 66.4 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 81.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 102 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 113 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss | 120 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 11 lbs/1000ft |
| Min Flexing Radius | 0.375 in |
| Maximum Recommended Pulling Tension | 26 lbs |
| Minimum Bend Radius During Operation | .375 in |
| Minimum Bend Radius During Installation | 0.125 in |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 24 |
| Conductor — Material | SC - Silvered Copper |
| Conductor — Stranding | Solid |
| Insulation — Material | PTFE - Polytetrafluoroethylene |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | No Jacket |
| Outer Shield Row 1 — Type | Tape |
| Outer Shield Row 2 — Type | Braid |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Conductor — Nominal Diameter | 0.02 in |
| Insulation — Nominal Diameter | 0.062 in |
| Outer Shield Row 1 — Material | Bare Copper (BC) |
| Outer Shield Row 2 — Material | Tinned Copper (TC + Tin Filled) |
| Insulation — Material Trade Name | Teflon® |
| Outer Shield Row 1 — Coverage [%] | 100% |
| Outer Shield Row 2 — Coverage [%] | 100% |
Applicable Environmental And Other Programs
| EU CE Mark | No |
| Environmental Space | Indoor/Outdoor |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing