Belden Store
Belden 1618A 0101000 — CATV Video, RG11, 14 AWG BCCS, Quad Shield , Waterblocked

Belden Cable

Belden|

MPN: 1618A 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1618A 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 14
  • Conductor Stranding: Solid
  • Conductor Material: BCCS - Bare Copper Covered Steel
  • Conductor Nominal Diameter: 0.064 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.28 in
  • Outer Jacket Material: PE - Polyethylene
Belden 1618A 0101000 is an orderable item number in the Belden 1618A family (Cable › Video Cable › CATV Cable). Series 11, 14 AWG solid .064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® IV quad shield (Foil + 60% Braid + Foil + 40% Braid), polyethylene jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825119296. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.389 Revision Date: 02-20-2026

Standards

RG Type11
Series Type11

This Item

UPC612825119296
ColorBlack
Length1,000 ft
Item Number1618A 0101000
Put-Up TypeReel

Suitability

Suitability - BurialYes
Suitability - IndoorYes
Suitability - OutdoorYes

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Operating Temperature Range-55°C To +80°C

Electrical Characteristics

Delay — Nominal Delay1.2 ns/ft
Return Loss — Frequency [MHz]5 - 1000 MHz
Inductance — Nominal Inductance0.097 μH/ft
Voltage — Non-UL Voltage Rating300 V RMS
Conductor DCR — Outer Conductor DCR3 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR11 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]5 MHz
High Frequency Row 2 — Frequency [MHz]55 MHz
High Frequency Row 3 — Frequency [MHz]211 MHz
High Frequency Row 4 — Frequency [MHz]270 MHz
High Frequency Row 5 — Frequency [MHz]300 MHz
High Frequency Row 6 — Frequency [MHz]350 MHz
High Frequency Row 7 — Frequency [MHz]400 MHz
High Frequency Row 8 — Frequency [MHz]450 MHz
High Frequency Row 9 — Frequency [MHz]550 MHz
High Frequency Row 10 — Frequency [MHz]750 MHz
High Frequency Row 11 — Frequency [MHz]870 MHz
High Frequency Row 12 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Outer Shield DCR3 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Return Loss — Min. Structural Return Loss (SRL)20 dB
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.2 pF/ft
High Frequency Row 1 — Max. Insertion Loss (Attenuation)0.38 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)0.96 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)1.9 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)2.13 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)2.25 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)2.42 dB/100ft
High Frequency Row 7 — Max. Insertion Loss (Attenuation)2.6 dB/100ft
High Frequency Row 8 — Max. Insertion Loss (Attenuation)2.75 dB/100ft
High Frequency Row 9 — Max. Insertion Loss (Attenuation)3.04 dB/100ft
High Frequency Row 10 — Max. Insertion Loss (Attenuation)3.65 dB/100ft
High Frequency Row 11 — Max. Insertion Loss (Attenuation)4.06 dB/100ft
High Frequency Row 12 — Max. Insertion Loss (Attenuation)4.35 dB/100ft

Mechanical Characteristics

Bulk Cable Weight52 lbs/1000ft
Minimum Minor Axis Bend Radius4.25 in
Maximum Recommended Pulling Tension308 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG14
Conductor — MaterialBCCS - Bare Copper Covered Steel
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Outer Shield Table NotesCoreGuard®
Conductor — No. Of Coax1
Outer Jacket — MaterialPE - Polyethylene
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 3 — TypeTape
Outer Shield Row 4 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Outer Shield Row 3 — Layer3
Outer Shield Row 4 — Layer4
Conductor — Nominal Diameter0.064 in
Insulation — Nominal Diameter0.28 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialAluminum
Outer Shield Row 3 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 4 — MaterialAluminum
Outer Jacket — Nominal Diameter0.407 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]60%
Outer Shield Row 3 — Coverage [%]100%
Outer Shield Row 4 — Coverage [%]40%
Outer Shield Row 1 — Material Trade NameDuofoil®
Outer Shield Row 3 — Material Trade NameDuofoil®

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceOutdoor - Water Exposure
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account