Belden 1407B J5C1000 — RGB Video, High Flex, #26-4 Coax Stranded BC

Belden Cable

Belden|

MPN: 1407B J5C1000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1407B J5C1000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 26
  • Conductor Stranding: 7x34
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.019 in
  • Conductor No. of Coax: 4
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.089 in
  • Inner Jacket Material: PVC - Polyvinyl Chloride
Belden 1407B J5C1000 is an orderable item number in the Belden 1407B family (Cable › Coax & Triax Cable › RG59 Cable). RGB Video Coax, 4-26 AWG stranded bare copper conductors, foam HDPE insulation, Duofoil® +95% tinned copper braid shield, inner PVC jackets, flexible PVC jacket This item: Color Black, Vivid Matte, Put-Up Type Reel, Length 1,000 ft, UPC 612825355090. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.333 Revision Date: 02-20-2026

Standards

RG TypeMini 59
Series Type59

This Item

UPC612825355090
ColorBlack, Vivid Matte
Length1,000 ft
Item Number1407B J5C1000
Put-Up TypeReel

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Non-UL Temp Rating60°C
Operating Temperature Range-40°C To +60°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.3 ns/ft
Return Loss — Frequency [MHz]10-40 MHz
Voltage — Non-UL Voltage Rating300 V RMS
High Frequency — Frequency [MHz]30 MHz
Return Loss — Minimum Return (RL)25 dB
Conductor DCR — Outer Conductor DCR8.6 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR41.5 Ohm/1000ft
Conductor DCR — Nominal Inner Shield DCR8.6 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]78%
High Frequency — Max. Insertion Loss (Attenuation)3.6 dB/100ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]30 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 11 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance41.5 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.6 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss1.3 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss1.8 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss3.1 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss3.9 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss5.4 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss7.5 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss10.4 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss13.5 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss15.2 dB/100ft
High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss15.9 dB/100ft
Capacitance — Nom. Capacitance Conductor To Other Conductor To Shield17.3 pF/ft

Mechanical Characteristics

Bulk Cable Weight93 lbs/1000ft
Minimum Minor Axis Bend Radius4.5 in
Maximum Recommended Pulling Tension138 lbs

Physical Characteristics (Overall)

Conductor Count4
Conductor — AWG26
Conductor — MaterialBC - Bare Copper
Conductor — Stranding7x34
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax4
Inner Jacket — MaterialPVC - Polyvinyl Chloride
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — MaterialNo Shield
Color Chart Row 1 — ColorRed
Color Chart Row 2 — ColorGreen
Color Chart Row 3 — ColorBlue
Color Chart Row 4 — ColorWhite
Inner Shield Row 1 — TypeTape
Inner Shield Row 2 — TypeBraid
Color Chart Row 1 — Number1
Color Chart Row 2 — Number2
Color Chart Row 3 — Number3
Color Chart Row 4 — Number4
Inner Shield Row 1 — Layer1
Inner Shield Row 2 — Layer2
Conductor — Nominal Diameter0.019 in
Inner Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Inner Shield Row 2 — MaterialTinned Copper (TC)
Insulation — Nominal Diameter0.089 in
Inner Jacket — Nominal Diameter0.146 in
Outer Jacket — Nominal Diameter0.435 in
Inner Shield Row 1 — Coverage [%]100%
Inner Shield Row 2 — Coverage [%]95%
Outer Jacket — Separator MaterialPolyester Tape
Inner Shield Row 1 — Material Trade NameDuofoil®

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceIndoor (Not Riser or Plenum)
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account