Belden Store
Belden 1370P 0101000 — Serial Digital Coax, RG59 Type, 20 AWG Solid BC, Foil + 85% TC Braid, CMP

Belden Cable

Belden|

MPN: 1370P 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1370P 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Commercial Video
  • Conductor AWG: 20
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.032 in
  • Conductor No. of Coax: 1
  • Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
  • Insulation Material Trade Name: Teflon®
Belden 1370P 0101000 is an orderable item number in the Belden 1370P family (Cable › Video Cable › Coaxial Video Cable). Video Cable, RG-59 Type 20 AWG solid bare copper, foam FEP insulation, Bonded Duofoil®+85% tinned copper braid, CMP Flamarrest® jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825113300. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.332 Revision Date: 02-20-2026

Standards

RG Type59
NEC/(UL) ComplianceCMP
CEC/C(UL) ComplianceCMP

This Item

UPC612825113300
ColorBlack
Length1,000 ft
Item Number1370P 0101000
Put-Up TypeReel

Suitability

Suitability - IndoorYes
Suitability - OutdoorNo

Product Overview

Suitable ApplicationsCommercial Video

Plenum/Non-Plenum

Plenum (Y/N)Yes

Temperature Range

UL Temperature Rating75°C
Operating Temperature Range0°C To +75°C

Related Part Numbers

Non-Plenum Number1370R

Electrical Characteristics

Delay — Nominal Delay1.21 ns/ft
Voltage — UL Voltage Rating300 V RMS
Return Loss — Frequency [MHz]5 - 3000 MHz
Electrical Characteristics NotesReturn Loss: Fixed bridge and termination
Inductance — Nominal Inductance0.097 μH/ft
Return Loss — Minimum Return (RL)15 dB
Conductor DCR — Outer Conductor DCR4.1 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR10.1 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR4.1 Ohm/1000ft
High Frequency — Min. RL (Return Loss) [DB]15 dB
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]84%
Capacitance — Nom. Capacitance Conductor To Shield16.1 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]3.58 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]7 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]67.5 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]71.5 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]135 MHz
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]143 MHz
High Frequency (Nominal/Typical) Row 11 — Frequency [MHz]180 MHz
High Frequency (Nominal/Typical) Row 12 — Frequency [MHz]270 MHz
High Frequency (Nominal/Typical) Row 13 — Frequency [MHz]360 MHz
High Frequency (Nominal/Typical) Row 14 — Frequency [MHz]540 MHz
High Frequency (Nominal/Typical) Row 15 — Frequency [MHz]720 MHz
High Frequency (Nominal/Typical) Row 16 — Frequency [MHz]750 MHz
High Frequency (Nominal/Typical) Row 17 — Frequency [MHz]1000 MHz
High Frequency (Nominal/Typical) Row 18 — Frequency [MHz]1500 MHz
High Frequency (Nominal/Typical) Row 19 — Frequency [MHz]2250 MHz
High Frequency (Nominal/Typical) Row 20 — Frequency [MHz]3000 MHz
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.29 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.62 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss0.7 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss0.82 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss1.05 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss2.2 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss2.25 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss2.7 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss3.2 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss3.25 dB/100ft
High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss3.65 dB/100ft
High Frequency (Nominal/Typical) Row 12 — Nom. Insertion Loss4.55 dB/100ft
High Frequency (Nominal/Typical) Row 13 — Nom. Insertion Loss5.25 dB/100ft
High Frequency (Nominal/Typical) Row 14 — Nom. Insertion Loss6.4 dB/100ft
High Frequency (Nominal/Typical) Row 15 — Nom. Insertion Loss7.3 dB/100ft
High Frequency (Nominal/Typical) Row 16 — Nom. Insertion Loss7.5 dB/100ft
High Frequency (Nominal/Typical) Row 17 — Nom. Insertion Loss9.4 dB/100ft
High Frequency (Nominal/Typical) Row 18 — Nom. Insertion Loss12.8 dB/100ft
High Frequency (Nominal/Typical) Row 19 — Nom. Insertion Loss17.5 dB/100ft
High Frequency (Nominal/Typical) Row 20 — Nom. Insertion Loss21.9 dB/100ft

Mechanical Characteristics

Bulk Cable Weight24 lbs/1000ft
Minimum Minor Axis Bend Radius2 in
Maximum Recommended Pulling Tension37 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG20
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.032 in
Insulation — Nominal Diameter0.133 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialTinned Copper (TC)
Outer Jacket — Nominal Diameter0.192 in
Insulation — Material Trade NameTeflon®
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]85%
Outer Jacket — Material Trade NameFlamarrest®
Outer Shield Row 1 — Material Trade NameDuobond® II

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

Environmental SpaceIndoor - Plenum
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account