Key Features

  • Suitable Applications: Commercial Video
  • Conductor AWG: 18
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.04 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.17 in
Belden 1369R 0101000 is an orderable item number in the Belden 1369R family (Cable › Video Cable › Coaxial Video Cable). Video Cable , Riser-CMR, RG6, 18 AWG solid bare copper, foam polyethylene insulation, Duofoil®; 85% tinned copper braid, PVC jacket This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825113102. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.375 Revision Date: 02-20-2026

Standards

RG Type6
NEC/(UL) ComplianceCMR
CEC/C(UL) ComplianceCMR

This Item

UPC612825113102
ColorBlack
Length1,000 ft
Item Number1369R 0101000
Put-Up TypeReel

Suitability

Suitability - IndoorYes
Suitability - OutdoorNo

Product Overview

Suitable ApplicationsCommercial Video

Plenum/Non-Plenum

Plenum (Y/N)No
Plenum Number1369P

Temperature Range

UL Temperature Rating75°C
Operating Temperature Range-30°C To +75°C

Electrical Characteristics

Delay — Nominal Delay1.21 ns/ft
Voltage — UL Voltage Rating300 V RMS
Return Loss — Frequency [MHz]5-3000 MHz
Inductance — Nominal Inductance0.106 μH/ft
Return Loss — Minimum Return (RL)15 dB
Conductor DCR — Outer Conductor DCR3.6 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR6.4 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR3.6 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]84%
Capacitance — Nom. Capacitance Conductor To Shield16.6 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]3.58 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]6 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]7 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]12 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]25 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]67.5 MHz
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]71.5 MHz
High Frequency (Nominal/Typical) Row 11 — Frequency [MHz]88.5 MHz
High Frequency (Nominal/Typical) Row 12 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 13 — Frequency [MHz]135 MHz
High Frequency (Nominal/Typical) Row 14 — Frequency [MHz]143 MHz
High Frequency (Nominal/Typical) Row 15 — Frequency [MHz]180 MHz
High Frequency (Nominal/Typical) Row 16 — Frequency [MHz]270 MHz
High Frequency (Nominal/Typical) Row 17 — Frequency [MHz]360 MHz
High Frequency (Nominal/Typical) Row 18 — Frequency [MHz]540 MHz
High Frequency (Nominal/Typical) Row 19 — Frequency [MHz]720 MHz
High Frequency (Nominal/Typical) Row 20 — Frequency [MHz]750 MHz
High Frequency (Nominal/Typical) Row 21 — Frequency [MHz]1000 MHz
High Frequency (Nominal/Typical) Row 22 — Frequency [MHz]1500 MHz
High Frequency (Nominal/Typical) Row 23 — Frequency [MHz]2000 MHz
High Frequency (Nominal/Typical) Row 24 — Frequency [MHz]2250 MHz
High Frequency (Nominal/Typical) Row 25 — Frequency [MHz]3000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance6.4 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.24 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.44 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss0.52 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss0.57 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss0.61 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss0.71 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss0.78 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss1.08 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss1.65 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss1.69 dB/100ft
High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss1.86 dB/100ft
High Frequency (Nominal/Typical) Row 12 — Nom. Insertion Loss1.95 dB/100ft
High Frequency (Nominal/Typical) Row 13 — Nom. Insertion Loss2.24 dB/100ft
High Frequency (Nominal/Typical) Row 14 — Nom. Insertion Loss2.3 dB/100ft
High Frequency (Nominal/Typical) Row 15 — Nom. Insertion Loss2.57 dB/100ft
High Frequency (Nominal/Typical) Row 16 — Nom. Insertion Loss3.17 dB/100ft
High Frequency (Nominal/Typical) Row 17 — Nom. Insertion Loss3.69 dB/100ft
High Frequency (Nominal/Typical) Row 18 — Nom. Insertion Loss4.6 dB/100ft
High Frequency (Nominal/Typical) Row 19 — Nom. Insertion Loss5.38 dB/100ft
High Frequency (Nominal/Typical) Row 20 — Nom. Insertion Loss5.5 dB/100ft
High Frequency (Nominal/Typical) Row 21 — Nom. Insertion Loss6.42 dB/100ft
High Frequency (Nominal/Typical) Row 22 — Nom. Insertion Loss7.99 dB/100ft
High Frequency (Nominal/Typical) Row 23 — Nom. Insertion Loss9.37 dB/100ft
High Frequency (Nominal/Typical) Row 24 — Nom. Insertion Loss10.01 dB/100ft
High Frequency (Nominal/Typical) Row 25 — Nom. Insertion Loss11.78 dB/100ft

Mechanical Characteristics

Bulk Cable Weight29 lbs/1000ft
Minimum Minor Axis Bend Radius2.35 in
Maximum Recommended Pulling Tension64 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG18
Conductor — MaterialBC - Bare Copper
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.04 in
Insulation — Nominal Diameter0.17 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialTinned Copper (TC)
Outer Jacket — Nominal Diameter0.235 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]85%
Outer Shield Row 1 — Material Trade NameDuobond® II

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1666 Vertical Shaft
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
Environmental SpaceIndoor - Riser
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account