Key Features
- Suitable Applications: Commercial Video
- Conductor AWG: 18
- Conductor Stranding: Solid
- Conductor Material: BC - Bare Copper
- Conductor Nominal Diameter: 0.04 in
- Conductor No. of Coax: 1
- Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
- Insulation Material Trade Name: Teflon®
Belden 1369P 0101000 is an orderable item number in the Belden 1369P family (Cable › Video Cable › Coaxial Video Cable). Video Cable, Plenum-CMP, RG6, 18 AWG solid bare copper, foam FEP insulation, Duofoil®; 85% tinned copper braid, Flamarrest® jacket This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825112907. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.322 Revision Date: 02-20-2026 |
Standards
| RG Type | 6 |
| NEC/(UL) Compliance | CMP |
| CEC/C(UL) Compliance | CMP |
This Item
| UPC | 612825112907 |
| Color | Black |
| Length | 1,000 ft |
| Item Number | 1369P 0101000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Indoor | Yes |
| Suitability - Outdoor | No |
Product Notes
| Notes | Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc. |
Product Overview
| Suitable Applications | Commercial Video |
Plenum/Non-Plenum
| Plenum (Y/N) | Yes |
Temperature Range
| UL Temperature Rating | 75°C |
| Operating Temperature Range | -20°C To +75°C |
Related Part Numbers
| Non-Plenum Number | 1369R |
Electrical Characteristics
| Delay — Nominal Delay | 1.22 ns/ft |
| Voltage — UL Voltage Rating | 300 V RMS |
| Return Loss — Frequency [MHz] | 5-3000 MHz |
| Inductance — Nominal Inductance | 0.103 μH/ft |
| Return Loss — Minimum Return (RL) | 15 dB |
| Conductor DCR — Outer Conductor DCR | 3.6 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 6.4 Ohm/1000ft |
| Conductor DCR — Nominal Outer Shield DCR | 3.6 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 75 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 83% |
| Capacitance — Nom. Capacitance Conductor To Shield | 16.3 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 3.58 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 5 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 7 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 10 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 67.5 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 71.5 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 88.5 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 100 MHz |
| High Frequency (Nominal/Typical) Row 10 — Frequency [MHz] | 135 MHz |
| High Frequency (Nominal/Typical) Row 11 — Frequency [MHz] | 143 MHz |
| High Frequency (Nominal/Typical) Row 12 — Frequency [MHz] | 180 MHz |
| High Frequency (Nominal/Typical) Row 13 — Frequency [MHz] | 270 MHz |
| High Frequency (Nominal/Typical) Row 14 — Frequency [MHz] | 360 MHz |
| High Frequency (Nominal/Typical) Row 15 — Frequency [MHz] | 540 MHz |
| High Frequency (Nominal/Typical) Row 16 — Frequency [MHz] | 720 MHz |
| High Frequency (Nominal/Typical) Row 17 — Frequency [MHz] | 750 MHz |
| High Frequency (Nominal/Typical) Row 18 — Frequency [MHz] | 1000 MHz |
| High Frequency (Nominal/Typical) Row 19 — Frequency [MHz] | 1500 MHz |
| High Frequency (Nominal/Typical) Row 20 — Frequency [MHz] | 2000 MHz |
| High Frequency (Nominal/Typical) Row 21 — Frequency [MHz] | 2250 MHz |
| High Frequency (Nominal/Typical) Row 22 — Frequency [MHz] | 3000 MHz |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 6.4 Ohm/1000ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 0.24 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 0.45 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 0.55 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 0.65 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 0.75 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 1.74 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 1.78 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 1.94 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 2.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss | 2.4 dB/100ft |
| High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss | 2.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 12 — Nom. Insertion Loss | 2.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 13 — Nom. Insertion Loss | 3.4 dB/100ft |
| High Frequency (Nominal/Typical) Row 14 — Nom. Insertion Loss | 4 dB/100ft |
| High Frequency (Nominal/Typical) Row 15 — Nom. Insertion Loss | 5.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 16 — Nom. Insertion Loss | 6.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 17 — Nom. Insertion Loss | 6.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 18 — Nom. Insertion Loss | 7.3 dB/100ft |
| High Frequency (Nominal/Typical) Row 19 — Nom. Insertion Loss | 9.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 20 — Nom. Insertion Loss | 10.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 21 — Nom. Insertion Loss | 11.6 dB/100ft |
| High Frequency (Nominal/Typical) Row 22 — Nom. Insertion Loss | 13.7 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 33.5 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 2.5 in |
| Maximum Recommended Pulling Tension | 64 lbs |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 18 |
| Conductor — Material | BC - Bare Copper |
| Conductor — Stranding | Solid |
| Insulation — Material | FEP - Fluorinated Ethylene Propylene (Foam) |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield Row 1 — Type | Tape |
| Outer Shield Row 2 — Type | Braid |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Conductor — Nominal Diameter | 0.04 in |
| Insulation — Nominal Diameter | 0.168 in |
| Outer Shield Row 1 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield Row 2 — Material | Tinned Copper (TC) |
| Outer Jacket — Nominal Diameter | 0.231 in |
| Insulation — Material Trade Name | Teflon® |
| Outer Shield Row 1 — Coverage [%] | 100% |
| Outer Shield Row 2 — Coverage [%] | 85% |
| Outer Jacket — Material Trade Name | Flamarrest® |
| Outer Shield Row 1 — Material Trade Name | Duobond® II |
Flammability, LS0H, Toxicity Testing
| UL Flammability | NFPA 262 |
| CSA Flammability | FT6 |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | No |
| Environmental Space | Indoor - Plenum |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing