- Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.
- Conductor Element: Pair(s)
- Conductor AWG: 16
- Conductor Stranding: 7x24
- Conductor Material: TC - Tinned Copper
- Conductor Nominal Diameter: 0.059 in
- Conductor No. of Pairs: 2
- Insulation Material: PP - Polypropylene
Belden 1361A 0031000 is an orderable item number in the Belden 1361A family (Cable › Electronic Wire & Cable › Multi-Pair Cable). Fieldbus, 2 Pair 16AWG (7x24H) Tinned Copper, PO Insulation, Individual & Overall Beldfoil® Shield, Orange PVC Outer Jacket, CMG This item: Color Orange, Put-Up Type Reel, Length 1,000 ft, UPC 612825112648. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.490 Revision Date: 04-02-2026 |
Standards
| NEC Articles | Article 725, Article 727, Article 800 |
| CPR Euroclass | Eca |
| NEC/(UL) Compliance | CMG, ITC-ER, PLTC-ER |
| CEC/C(UL) Compliance | CMG |
This Item
| UPC | 612825112648 |
| Color | Orange |
| Length | 1,000 ft |
| Item Number | 1361A 0031000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Burial | Yes |
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Oil Resistance | Yes |
| Suitability - Sunlight Resistance | Yes |
Product Overview
| Suitable Applications | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| UL Temperature Rating | 105°C |
| Operating Temperature Range | -40°C to +105°C |
Electrical Characteristics
| Current — Element | Per Conductor |
| Voltage — UL Voltage Rating | 300 V RMS |
| Electrical Characteristics Notes | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
| Inductance — Nominal Inductance | 0.19 μH/ft |
| Other Electrical Characteristic 2 | 31.25 KBits/sec |
| Capacitance — Nom. Mutual Capacitance | 24 pF/ft |
| Conductor DCR — Nominal Conductor DCR | 4.2 Ohm/1000ft |
| Current — Max. Recommended Current [A] | 5.2 Amps per Conductor |
| Capacitance — Max. Capacitance Unbalance | 1.2 pF/ft |
| Conductor DCR — Nominal Outer Shield DCR | 4.9 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 100 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 66% |
| Capacitance — Nom. Capacitance Conductor To Shield | 45 pF/ft |
| Conductor DCR — Individual Pair Nominal Shield DCR | 7.5 Ohm/1000ft |
| High Frequency (Nominal/Typical) — Frequency [MHz] | 0.039 MHz |
| High Frequency — Max. Insertion Loss (Attenuation) | 0.091 dB/100ft |
| High Frequency — Max./Min. Input Impedance (UnFitted) | 100 Ohm |
| High Frequency (Nominal/Typical) — Nom. Insertion Loss | 0.08 dB/100ft |
Mechanical Characteristics
| UV Resistance | Yes |
| Oil Resistance | Yes |
| Bulk Cable Weight | 130 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 5.8 in |
| Maximum Recommended Pulling Tension | 143 lbs |
Construction And Dimensions
| Stranding — Twists | 5 twist/ft |
Physical Characteristics (Overall)
| Conductor Count | 4 |
| Conductor — AWG | 16 |
| Conductor — Element | Pair(s) |
| Inner Shield — Type | Tape |
| Outer Shield — Type | Tape |
| Conductor — Material | TC - Tinned Copper |
| Conductor — Stranding | 7x24 |
| Insulation — Material | PP - Polypropylene |
| Inner Shield — Material | Bi-Laminate (Alum+Poly) |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield — Material | Bi-Laminate (Alum+Poly) |
| Conductor — No. Of Pairs | 2 |
| Color Chart Row 1 — Color | Blue, Orange and Numbered |
| Color Chart Row 1 — Number | 1 |
| Color Chart Row 2 — Number | 2 |
| Inner Shield — Coverage [%] | 100% |
| Outer Shield — Coverage [%] | 100% |
| Conductor — Nominal Diameter | 0.059 in |
| Inner Shield — Drainwire AWG | 20 |
| Outer Shield — Drainwire AWG | 16 |
| Outer Jacket — Nominal Diameter | 0.577 in |
| Inner Shield — Drainwire Material | TC - Tinned Copper |
| Outer Shield — Drainwire Material | TC - Tinned Copper |
| Inner Shield — Material Trade Name | Beldfoil® |
| Outer Shield — Material Trade Name | Beldfoil® |
| Insulation — Nominal Wall Thickness | 0.029 in |
| Outer Jacket — Nominal Wall Thickness | 0.055 in |
| Outer Shield — Drainwire Construction N X D | 7x24 |
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 FT4 Loading |
| IEC Flammability | IEC 60332-3-24 |
| IEEE Flammability | 1202 |
| UL Voltage Rating | 300 V RMS |
| CSA/C(UL) Flammability | FT4 |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |