Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1335A 0061000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.
- Conductor AWG: 16
- Conductor Stranding: 7x24
- Conductor Material: TC - Tinned Copper
- Conductor No. of Pairs: 1
- Insulation Material: PP - Polypropylene
- Color Chart Number: 1
- Color Chart Color: Blue & Orange
Belden 1335A 0061000 is an orderable item number in the Belden 1335A family (Cable › Electronic Wire & Cable › Multi-Pair Cable). Fieldbus, 2 Conductor 16AWG (7x24H) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(65%) Shield, Orange PVC Outer Jacket, CM This item: Color Blue, Light, Put-Up Type Reel, Length 1,000 ft, UPC 612825112198. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.510 Revision Date: 04-02-2026 |
Standards
| NEC Articles | Article 725, Article 727, Article 800 |
| CPR Euroclass | Eca |
| NEC/(UL) Compliance | CM, ITC, PLTC |
| CEC/C(UL) Compliance | CM |
This Item
| UPC | 612825112198 |
| Color | Blue, Light |
| Length | 1,000 ft |
| Item Number | 1335A 0061000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Burial | Yes - UL |
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Oil Resistance | Yes |
| Suitability - Sunlight Resistance | Yes |
Product Overview
| Suitable Applications | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| UL Temperature Rating | 90°C |
| Operating Temperature Range | -30°C to +90°C |
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
Electrical Characteristics
| Current — Element | Per Conductor |
| Voltage — UL Voltage Rating | 300 V RMS |
| Electrical Characteristics Notes | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
| Other Electrical Characteristic 2 | 31.25 KBits/sec |
| Capacitance — Nom. Mutual Capacitance | 24 pF/ft |
| Conductor DCR — Max. Outer Shield DCR | 4.9 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 4.2 Ohm/1000ft |
| Current — Max. Recommended Current [A] | 8 Amps per Conductor |
| Capacitance — Max. Capacitance Unbalance | 1.2 pF/ft |
| Impedance — Nominal Characteristic Impedance | 100 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 66% |
| Capacitance — Nom. Capacitance Conductor To Shield | 45 pF/ft |
| High Frequency — Max. Insertion Loss (Attenuation) | 0.091 dB/100ft |
| High Frequency — Max./Min. Input Impedance (UnFitted) | 100 Ohm |
| High Frequency (Nominal/Typical) — Nom. Insertion Loss | 0.066 dB/100ft |
Mechanical Characteristics
| UV Resistance | Yes |
| Oil Resistance | Yes |
| Bulk Cable Weight | 79 lbs |
| Minimum Minor Axis Bend Radius | 3.4 in |
| Maximum Recommended Pulling Tension | 84 lbs |
Physical Characteristics (Overall)
| Conductor Count | 2 |
| Conductor — AWG | 16 |
| Color Chart — Color | Blue & Orange |
| Color Chart — Number | 1 |
| Conductor — Material | TC - Tinned Copper |
| Conductor — Stranding | 7x24 |
| Insulation — Material | PP - Polypropylene |
| Outer Jacket — Ripcord | Yes |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor — No. Of Pairs | 1 |
| Outer Shield Row 1 — Type | Tape |
| Outer Shield Row 2 — Type | Braid |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Outer Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Outer Shield Row 2 — Material | Tinned Copper (TC) |
| Outer Jacket — Nominal Diameter | 0.34 in |
| Outer Shield Row 1 — Coverage [%] | 100% |
| Outer Shield Row 2 — Coverage [%] | 65% |
| Outer Shield Row 1 — Drainwire AWG | 20 |
| Outer Shield Row 1 — Drainwire Material | TC - Tinned Copper |
| Outer Shield Row 1 — Material Trade Name | Beldfoil® |
| Outer Shield Row 1 — Drainwire Construction N X D | 7x28 |
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 UL Loading |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing