Belden Store
Belden 123107A 0105000 — RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM, PLTC

Belden Cable

Belden|

MPN: 123107A 0105000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 123107A 0105000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: exposure to rodent, crush, or cut through force, burial, serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, outdoor such as solar, lighting, etc.
  • Conductor Element: Pair(s)
  • Conductor No. of Elements: 2
  • Conductor Size: 22 AWG
  • Conductor Stranding: 7x30
  • Conductor Material: TC - Tinned Copper
  • Insulation Element: Pair(s)
  • Insulation Material: PE - Polyethylene (Foam)
Belden 123107A 0105000 is an orderable item number in the Belden 123107A family (Cable › Electronic Wire & Cable › Multi-Pair Cable). RS-485, 2 Pair 22AWG (7x30) Tinned Copper, PE Insulation, Overall Beldfoil®+Tinned Copper Braid(65%) Shield, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, CM, PLTC This item: Color Black, Putup Type Reel, Length 5,000 ft, UPC 612825109631, Footnote C Z. Ships from and sold by A5 IT. Quoted to order.

History

FootnoteC - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Update And RevisionRevision Number: 0.404 Revision Date: 02-20-2026

This Item

UPC612825109631
ColorBlack
Length5,000 ft
FootnoteC Z
Putup TypeReel
Item Number123107A 0105000

Product Overview

Suitable Applicationsexposure to rodent, crush, or cut through force, burial, serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, outdoor such as solar, lighting, etc.

Construction Details

Conductor — Size22 AWG
Insulation — NotesHDPE
Conductor — ElementPair(s)
Conductor — MaterialTC - Tinned Copper
Insulation — ElementPair(s)
Conductor — Stranding7x30
Insulation — MaterialPE - Polyethylene (Foam)
Armor — Armor Thickness0.025 in
Inner Jacket — MaterialPVC - Polyvinyl Chloride
Insulation — Color CodeWhite/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor — No. Of Elements2
Insulation — Nom. Thickness0.025 in (0.64 mm)
Inner Jacket — Nom. Diameter0.350 in (8.89 mm)
Outer Jacket — Nom. Diameter0.690 in (17.5 mm)
Armor — Armor Type & MaterialAIA - Aluminum Interlock Armor
Inner Jacket — Nom. Thickness0.053 in (1.3 mm)
Outer Jacket — Nom. Thickness0.045 in (1.1 mm)
Outer Shield Row 1 — Coverage100%
Outer Shield Row 1 — MaterialBi-Laminate (Alum+Poly)
Outer Shield Row 2 — Coverage65%
Outer Shield Row 2 — MaterialTinned Copper (TC)
Overall Cable Diameter (Nominal)0.690 in (17.5 mm)
Armor — Armor Material Diameter0.560 in
Outer Shield Row 1 — Shield TypeTape
Outer Shield Row 2 — Shield TypeBraid
Outer Shield Row 1 — Drainwire Type22 AWG (7x30) TC
Insulation — Nom. Insulation Diameter0.079 in (2.0 mm)

Standards And Compliance

APAC ComplianceChina RoHS II (GB/T 26572-2011)
NEC / UL ComplianceArticle 725, Article 800, CM, PLTC
CEC / C(UL) ComplianceCMG, HLBCD.
Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL 1685 UL Loading, IEEE 1202

Electrical Characteristics

Nom Outer Shield DCR2.95 Ohm/1000ft (9.68 Ohm/km)
Electricals — ElementPair(s)
Electricals — Max. Current2.7 Amps per Conductor at 25oC
Voltage — UL Voltage Rating300 V
Electricals — Nom. Conductor DCR18.7 Ohm/1000ft
Electricals — Nom. Velocity Of Prop.78%
High Frequency (Nominal/Typical) — ElementPair(s)
Electricals — Nom. Capacitance Cond-to-Cond11 pF/ft (36 pF/m)
Electricals — Nom. Characteristic Impedence120 Ohm
High Frequency (Nominal/Typical) — Frequency [MHz]1
Electricals — Nom. Capacitance Cond-to-Other (Conds + Shield)20.9 pF/ft (68.6 pF/m)
High Frequency (Nominal/Typical) — Nom. Insertion Loss (Attenuation)0.5 dB/100ft

Mechanical Characteristics

Bulk Cable Weight172 lbs/1000ft
Max. Pull Tension200 lbs (91 kg)
Temperature Table Notes-40C
Temperature — Operating-40°C to +60°C
Temperature — Installation-20°C To +60°C
Temperature — UL Temperature60°C
Bend Radius — Stationary Min.8.5 in (220 mm)
Bend Radius — Installation Min.8.5 in (220 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account