Belden Store
Belden 1190A 0101000 — CATV Video, RG6, 18 AWG BCCS, Quad Shield (Foil + 60% Braid + Foil + 40% Braid), Waterblocked

Belden Cable

Belden|

MPN: 1190A 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 1190A 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: CATV, Broadband
  • Conductor AWG: 18
  • Conductor Stranding: Solid
  • Conductor Material: BCCS - Bare Copper Covered Steel
  • Conductor Nominal Diameter: 0.04 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.18 in
Belden 1190A 0101000 is an orderable item number in the Belden 1190A family (Cable › Video Cable › CATV Cable). Series 6, 18 AWG solid .040" bare copper-covered steel conductor with Coreguard, gas-injected foam polyethylene insulation, with Coreguard® and flooding compound, Duobond® IV quad shield (60% and 40% coverage), polyethylene jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825309727. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.392 Revision Date: 02-20-2026

Standards

RG Type6
Series Type6

This Item

UPC612825309727
ColorBlack
Length1,000 ft
Item Number1190A 0101000
Put-Up TypeReel

Suitability

Suitability - AerialYes - When supported by messenger wire
Suitability - BurialYes
Suitability - IndoorNo
Suitability - OutdoorYes
Suitability - Hazardous LocationsNo
Suitability - Sunlight ResistanceNo

Product Overview

Suitable ApplicationsCATV, Broadband

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Operating Temperature Range-55°C To +80°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.2 ns/ft
Inductance — Nominal Inductance0.097 μH/ft
Voltage — Non-UL Voltage Rating350 V RMS
Conductor DCR — Outer Conductor DCR4.8 Ohm/1000ft
Return Loss Row 1 — Frequency [MHz]5 MHz
Return Loss Row 2 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR28 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]5 MHz
High Frequency Row 2 — Frequency [MHz]55 MHz
High Frequency Row 3 — Frequency [MHz]211 MHz
High Frequency Row 4 — Frequency [MHz]270 MHz
High Frequency Row 5 — Frequency [MHz]300 MHz
High Frequency Row 6 — Frequency [MHz]350 MHz
High Frequency Row 7 — Frequency [MHz]400 MHz
High Frequency Row 8 — Frequency [MHz]450 MHz
High Frequency Row 9 — Frequency [MHz]550 MHz
High Frequency Row 10 — Frequency [MHz]750 MHz
High Frequency Row 11 — Frequency [MHz]870 MHz
High Frequency Row 12 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Outer Shield DCR4.8 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.2 pF/ft
Return Loss Row 1 — Min. Structural Return Loss (SRL)20 dB
Return Loss Row 2 — Min. Structural Return Loss (SRL)20 dB
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]55 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]211 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]270 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]300 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]350 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]450 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]550 MHz
High Frequency Row 1 — Max. Insertion Loss (Attenuation)0.67 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)1.6 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)2.87 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)3.24 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)3.43 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)3.72 dB/100ft
High Frequency Row 7 — Max. Insertion Loss (Attenuation)4 dB/100ft
High Frequency Row 8 — Max. Insertion Loss (Attenuation)4.26 dB/100ft
High Frequency Row 9 — Max. Insertion Loss (Attenuation)4.71 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]750 MHz
High Frequency (Nominal/Typical) Row 11 — Frequency [MHz]870 MHz
High Frequency (Nominal/Typical) Row 12 — Frequency [MHz]1000 MHz
High Frequency Row 10 — Max. Insertion Loss (Attenuation)5.59 dB/100ft
High Frequency Row 11 — Max. Insertion Loss (Attenuation)6 dB/100ft
High Frequency Row 12 — Max. Insertion Loss (Attenuation)6.54 dB/100ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.67 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss1.60 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss2.87 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss3.24 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss3.43 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss3.72 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss4.00 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss4.26 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss4.71 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss5.59 dB/100ft
High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss6.00 dB/100ft
High Frequency (Nominal/Typical) Row 12 — Nom. Insertion Loss6.54 dB/100ft

Mechanical Characteristics

Bulk Cable Weight28 lbs/1000ft
Minimum Minor Axis Bend Radius3 in
Maximum Recommended Pulling Tension162 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG18
Conductor — MaterialBCCS - Bare Copper Covered Steel
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Outer Shield Table NotesCoreGuard®
Conductor — No. Of Coax1
Outer Jacket — MaterialPE - Polyethylene
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 3 — TypeTape
Outer Shield Row 4 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Outer Shield Row 3 — Layer3
Outer Shield Row 4 — Layer4
Conductor — Nominal Diameter0.04 in
Insulation — Nominal Diameter0.18 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialAluminum
Outer Shield Row 3 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 4 — MaterialAluminum
Outer Jacket — Nominal Diameter0.298 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]60%
Outer Shield Row 3 — Coverage [%]100%
Outer Shield Row 4 — Coverage [%]40%
Outer Shield Row 1 — Material Trade NameDuofoil®
Outer Shield Row 3 — Material Trade NameDuofoil®

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceOutdoor - Water Exposure
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account