Key Features
- Suitable Applications: Premise Horizontal Cable, Ethernet 10GBASE-T, Wi-Fi 6, Wi-Fi 5, In-Building Wireless, In-Building Small Cells, Mobile RAN, PoE++, PoE+, PoE, HDBaseT
- Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
- Conductor Size: 23 AWG
- Conductor Stranding: Solid
- Conductor Material: BC - Bare Copper
- Conductor No. of Pairs: 4
- Insulation Material: FEP - Fluorinated Ethylene Propylene
- Insulation Color Code: White & Blue, White & Orange, White & Green, White & Brown
Belden 10GXW13003A1000 is an orderable item number in the Belden 10GXW13 family (Cable › Ethernet Cable › Category 6A Cable). 10GXW (0.250" Diameter) Category 6A Premise Horizontal Cable (500MHz), 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP, Flamarrest® PVC-LS Jacket This item: Color Orange, Putup Type Reel in Box, Length 1,000 ft, UPC 612825481423. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.320 Revision Date: 04-30-2026 |
This Item
| UPC | 612825481423 |
| Color | Orange |
| Length | 1,000 ft |
| Putup Type | Reel in Box |
| Item Number | 10GXW13003A1000 |
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. |
Product Overview
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents . |
| Suitable Applications | Premise Horizontal Cable, Ethernet 10GBASE-T, Wi-Fi 6, Wi-Fi 5, In-Building Wireless, In-Building Small Cells, Mobile RAN, PoE++, PoE+, PoE, HDBaseT |
Construction Details
| Conductor — Size | 23 AWG |
| Conductor — Material | BC - Bare Copper |
| Conductor — Stranding | Solid |
| Insulation — Material | FEP - Fluorinated Ethylene Propylene |
| Outer Jacket — Ripcord | Yes |
| Insulation — Color Code | White & Blue, White & Orange, White & Green, White & Brown |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor — No. Of Pairs | 4 |
| Outer Jacket — Separator | Center Member (Patented X-Spline®), EquiBlockTM Barrier Technology |
| Outer Jacket — Nom. Diameter | 0.250 in (6.35 mm) |
| Overall Cable Diameter (Nominal) | 0.250 in (6.35 mm) |
| Outer Jacket — Material Trade Name | Flamarrest® |
Standards And Compliance
| Data Category | Category 6A |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| ICEA Compliance | S-116-732 |
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| NEMA Compliance | ANSI/NEMA WC-66 |
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
| NEC / UL Compliance | Article 800, CMP, CMP-LP (0.5A), CL3P-LP (0.5A) |
| CEC / C(UL) Compliance | CMP. |
| Environmental Suitability | Plenum, Indoor |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
| Flammability / Reaction To Fire | NFPA 262, UL 910 (Plenum), FT6 |
Electrical Characteristics
| Delay — Max. Delay | 537.6 ns/100m |
| Delay — Max. Delay Skew | 45 ns/100m |
| Voltage — UL Voltage Rating | 300 V (CMP) |
| Delay — Nom. Velocity Of Prop. | 69% |
| Electricals — Max. Conductor DCR | 82 Ohm/km (25 Ohm/1000ft) |
| High Frequency Row 1 — Min. ACR [DB] | 72.2 |
| High Frequency Row 1 — Min. TCL [DB] | 40.0 |
| High Frequency Row 2 — Min. ACR [DB] | 61.5 |
| High Frequency Row 2 — Min. TCL [DB] | 40.0 |
| High Frequency Row 3 — Min. ACR [DB] | 55.4 |
| High Frequency Row 3 — Min. TCL [DB] | 40.0 |
| High Frequency Row 4 — Min. ACR [DB] | 53.4 |
| High Frequency Row 4 — Min. TCL [DB] | 40.0 |
| High Frequency Row 5 — Min. ACR [DB] | 48.8 |
| High Frequency Row 5 — Min. TCL [DB] | 38.0 |
| High Frequency Row 6 — Min. ACR [DB] | 46.4 |
| High Frequency Row 6 — Min. TCL [DB] | 37.0 |
| High Frequency Row 7 — Min. ACR [DB] | 44.0 |
| High Frequency Row 7 — Min. TCL [DB] | 36.0 |
| High Frequency Row 8 — Min. ACR [DB] | 41.4 |
| High Frequency Row 8 — Min. TCL [DB] | 35.1 |
| High Frequency Row 9 — Min. ACR [DB] | 32.4 |
| High Frequency Row 9 — Min. TCL [DB] | 32.0 |
| High Frequency Row 1 — Min. NEXT [DB] | 74.3 |
| High Frequency Row 10 — Min. ACR [DB] | 25.2 |
| High Frequency Row 10 — Min. TCL [DB] | 30.0 |
| High Frequency Row 11 — Min. ACR [DB] | 12.2 |
| High Frequency Row 11 — Min. TCL [DB] | 27.0 |
| High Frequency Row 12 — Min. ACR [DB] | 7.3 |
| High Frequency Row 12 — Min. TCL [DB] | 26.0 |
| High Frequency Row 13 — Min. ACR [DB] | 2.9 |
| High Frequency Row 13 — Min. TCL [DB] | 25.2 |
| High Frequency Row 14 — Min. TCL [DB] | 24.6 |
| High Frequency Row 15 — Min. TCL [DB] | 24.0 |
| High Frequency Row 16 — Min. TCL [DB] | 23.5 |
| High Frequency Row 17 — Min. TCL [DB] | 23.0 |
| High Frequency Row 2 — Min. NEXT [DB] | 65.3 |
| High Frequency Row 3 — Min. NEXT [DB] | 60.8 |
| High Frequency Row 4 — Min. NEXT [DB] | 59.3 |
| High Frequency Row 5 — Min. NEXT [DB] | 56.2 |
| High Frequency Row 6 — Min. NEXT [DB] | 54.8 |
| High Frequency Row 7 — Min. NEXT [DB] | 53.3 |
| High Frequency Row 8 — Min. NEXT [DB] | 51.9 |
| High Frequency Row 9 — Min. NEXT [DB] | 47.4 |
| High Frequency Row 1 — Frequency [MHz] | 1 |
| High Frequency Row 1 — Min. PSACR [DB] | 70.2 |
| High Frequency Row 10 — Min. NEXT [DB] | 44.3 |
| High Frequency Row 11 — Min. NEXT [DB] | 39.8 |
| High Frequency Row 12 — Min. NEXT [DB] | 38.3 |
| High Frequency Row 13 — Min. NEXT [DB] | 37.1 |
| High Frequency Row 14 — Min. NEXT [DB] | 36.1 |
| High Frequency Row 15 — Min. NEXT [DB] | 35.3 |
| High Frequency Row 16 — Min. NEXT [DB] | 34.5 |
| High Frequency Row 17 — Min. NEXT [DB] | 33.8 |
| High Frequency Row 2 — Frequency [MHz] | 4 |
| High Frequency Row 2 — Min. PSACR [DB] | 59.5 |
| High Frequency Row 3 — Frequency [MHz] | 8 |
| High Frequency Row 3 — Min. PSACR [DB] | 53.4 |
| High Frequency Row 4 — Frequency [MHz] | 10 |
| High Frequency Row 4 — Min. PSACR [DB] | 51.4 |
| High Frequency Row 5 — Frequency [MHz] | 16 |
| High Frequency Row 5 — Min. PSACR [DB] | 46.8 |
| High Frequency Row 6 — Frequency [MHz] | 20 |
| High Frequency Row 6 — Min. PSACR [DB] | 44.4 |
| High Frequency Row 7 — Frequency [MHz] | 25 |
| High Frequency Row 7 — Min. PSACR [DB] | 42.0 |
| High Frequency Row 8 — Frequency [MHz] | 31.25 |
| High Frequency Row 8 — Min. PSACR [DB] | 39.4 |
| High Frequency Row 9 — Frequency [MHz] | 62.5 |
| High Frequency Row 9 — Min. PSACR [DB] | 30.4 |
| High Frequency Row 1 — Min. ELTCTL [DB] | 35.0 |
| High Frequency Row 1 — Min. PSNEXT [DB] | 72.3 |
| High Frequency Row 10 — Frequency [MHz] | 100 |
| High Frequency Row 10 — Min. PSACR [DB] | 23.2 |
| High Frequency Row 11 — Frequency [MHz] | 200 |
| High Frequency Row 11 — Min. PSACR [DB] | 10.2 |
| High Frequency Row 12 — Frequency [MHz] | 250 |
| High Frequency Row 12 — Min. PSACR [DB] | 5.3 |
| High Frequency Row 13 — Frequency [MHz] | 300 |
| High Frequency Row 13 — Min. PSACR [DB] | 0.9 |
| High Frequency Row 14 — Frequency [MHz] | 350 |
| High Frequency Row 15 — Frequency [MHz] | 400 |
| High Frequency Row 16 — Frequency [MHz] | 450 |
| High Frequency Row 17 — Frequency [MHz] | 500 |
| High Frequency Row 2 — Min. ELTCTL [DB] | 23.0 |
| High Frequency Row 2 — Min. PSNEXT [DB] | 63.3 |
| High Frequency Row 3 — Min. ELTCTL [DB] | 16.9 |
| High Frequency Row 3 — Min. PSNEXT [DB] | 58.8 |
| High Frequency Row 4 — Min. ELTCTL [DB] | 15.0 |
| High Frequency Row 4 — Min. PSNEXT [DB] | 57.3 |
| High Frequency Row 5 — Min. ELTCTL [DB] | 10.9 |
| High Frequency Row 5 — Min. PSNEXT [DB] | 54.2 |
| High Frequency Row 6 — Min. ELTCTL [DB] | 9.0 |
| High Frequency Row 6 — Min. PSNEXT [DB] | 52.8 |
| High Frequency Row 7 — Min. ELTCTL [DB] | 7.0 |
| High Frequency Row 7 — Min. PSNEXT [DB] | 51.3 |
| High Frequency Row 8 — Min. ELTCTL [DB] | 5.1 |
| High Frequency Row 8 — Min. PSNEXT [DB] | 49.9 |
| High Frequency Row 9 — Min. PSNEXT [DB] | 45.4 |
| Electricals — Max. Capacitance Unbalance | 45 pF/100m |
| High Frequency Row 1 — Min. PSAACRF [DB] | 67.0 |
| High Frequency Row 1 — Min. PSANEXT [DB] | 67.0 |
| High Frequency Row 10 — Min. PSNEXT [DB] | 42.3 |
| High Frequency Row 11 — Min. PSNEXT [DB] | 37.8 |
| High Frequency Row 12 — Min. PSNEXT [DB] | 36.3 |
| High Frequency Row 13 — Min. PSNEXT [DB] | 35.1 |
| High Frequency Row 14 — Min. PSNEXT [DB] | 34.1 |
| High Frequency Row 15 — Min. PSNEXT [DB] | 33.3 |
| High Frequency Row 16 — Min. PSNEXT [DB] | 32.5 |
| High Frequency Row 17 — Min. PSNEXT [DB] | 31.8 |
| High Frequency Row 2 — Min. PSAACRF [DB] | 66.2 |
| High Frequency Row 2 — Min. PSANEXT [DB] | 67.0 |
| High Frequency Row 3 — Min. PSAACRF [DB] | 60.1 |
| High Frequency Row 3 — Min. PSANEXT [DB] | 67.0 |
| High Frequency Row 4 — Min. PSAACRF [DB] | 58.2 |
| High Frequency Row 4 — Min. PSANEXT [DB] | 67.0 |
| High Frequency Row 5 — Min. PSAACRF [DB] | 54.1 |
| High Frequency Row 5 — Min. PSANEXT [DB] | 67.0 |
| High Frequency Row 6 — Min. PSAACRF [DB] | 52.2 |
| High Frequency Row 6 — Min. PSANEXT [DB] | 67.0 |
| High Frequency Row 7 — Min. PSAACRF [DB] | 50.2 |
| High Frequency Row 7 — Min. PSANEXT [DB] | 67.0 |
| High Frequency Row 8 — Min. PSAACRF [DB] | 48.3 |
| High Frequency Row 8 — Min. PSANEXT [DB] | 67.0 |
| High Frequency Row 9 — Min. PSAACRF [DB] | 42.3 |
| High Frequency Row 9 — Min. PSANEXT [DB] | 65.6 |
| High Frequency Row 10 — Min. PSAACRF [DB] | 38.2 |
| High Frequency Row 10 — Min. PSANEXT [DB] | 62.5 |
| High Frequency Row 11 — Min. PSAACRF [DB] | 32.2 |
| High Frequency Row 11 — Min. PSANEXT [DB] | 58.0 |
| High Frequency Row 12 — Min. PSAACRF [DB] | 30.2 |
| High Frequency Row 12 — Min. PSANEXT [DB] | 56.5 |
| High Frequency Row 13 — Min. PSAACRF [DB] | 28.7 |
| High Frequency Row 13 — Min. PSANEXT [DB] | 55.3 |
| High Frequency Row 14 — Min. PSAACRF [DB] | 27.3 |
| High Frequency Row 14 — Min. PSANEXT [DB] | 54.3 |
| High Frequency Row 15 — Min. PSAACRF [DB] | 26.2 |
| High Frequency Row 15 — Min. PSANEXT [DB] | 53.5 |
| High Frequency Row 16 — Min. PSAACRF [DB] | 25.1 |
| High Frequency Row 16 — Min. PSANEXT [DB] | 52.7 |
| High Frequency Row 17 — Min. PSAACRF [DB] | 24.2 |
| High Frequency Row 17 — Min. PSANEXT [DB] | 52.0 |
| High Frequency Row 1 — Min. ACRF (ELFEXT) [DB] | 67.8 |
| High Frequency Row 2 — Min. ACRF (ELFEXT) [DB] | 55.8 |
| High Frequency Row 3 — Min. ACRF (ELFEXT) [DB] | 49.7 |
| High Frequency Row 4 — Min. ACRF (ELFEXT) [DB] | 47.8 |
| High Frequency Row 5 — Min. ACRF (ELFEXT) [DB] | 43.7 |
| High Frequency Row 6 — Min. ACRF (ELFEXT) [DB] | 41.8 |
| High Frequency Row 7 — Min. ACRF (ELFEXT) [DB] | 39.8 |
| High Frequency Row 8 — Min. ACRF (ELFEXT) [DB] | 37.9 |
| High Frequency Row 9 — Min. ACRF (ELFEXT) [DB] | 31.9 |
| High Frequency Row 10 — Min. ACRF (ELFEXT) [DB] | 27.8 |
| High Frequency Row 11 — Min. ACRF (ELFEXT) [DB] | 21.8 |
| High Frequency Row 12 — Min. ACRF (ELFEXT) [DB] | 19.8 |
| High Frequency Row 13 — Min. ACRF (ELFEXT) [DB] | 18.3 |
| High Frequency Row 14 — Min. ACRF (ELFEXT) [DB] | 16.9 |
| High Frequency Row 15 — Min. ACRF (ELFEXT) [DB] | 15.8 |
| High Frequency Row 16 — Min. ACRF (ELFEXT) [DB] | 14.7 |
| High Frequency Row 17 — Min. ACRF (ELFEXT) [DB] | 13.8 |
| High Frequency Row 1 — Min. RL (Return Loss) [DB] | 20.0 |
| High Frequency Row 2 — Min. RL (Return Loss) [DB] | 23.0 |
| High Frequency Row 3 — Min. RL (Return Loss) [DB] | 24.5 |
| High Frequency Row 4 — Min. RL (Return Loss) [DB] | 25.0 |
| High Frequency Row 5 — Min. RL (Return Loss) [DB] | 25.0 |
| High Frequency Row 6 — Min. RL (Return Loss) [DB] | 25.0 |
| High Frequency Row 7 — Min. RL (Return Loss) [DB] | 24.3 |
| High Frequency Row 8 — Min. RL (Return Loss) [DB] | 23.6 |
| High Frequency Row 9 — Min. RL (Return Loss) [DB] | 21.5 |
| High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB] | 64.8 |
| High Frequency Row 10 — Min. RL (Return Loss) [DB] | 20.1 |
| High Frequency Row 11 — Min. RL (Return Loss) [DB] | 18.0 |
| High Frequency Row 12 — Min. RL (Return Loss) [DB] | 17.3 |
| High Frequency Row 13 — Min. RL (Return Loss) [DB] | 16.8 |
| High Frequency Row 14 — Min. RL (Return Loss) [DB] | 16.3 |
| High Frequency Row 15 — Min. RL (Return Loss) [DB] | 15.9 |
| High Frequency Row 16 — Min. RL (Return Loss) [DB] | 15.5 |
| High Frequency Row 17 — Min. RL (Return Loss) [DB] | 15.2 |
| High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB] | 52.8 |
| High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB] | 46.7 |
| High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB] | 44.8 |
| High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB] | 40.7 |
| High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB] | 38.8 |
| High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB] | 36.8 |
| High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB] | 34.9 |
| High Frequency Row 9 — Min. PSACRF (PSELFEXT) [DB] | 28.9 |
| High Frequency Row 10 — Min. PSACRF (PSELFEXT) [DB] | 24.8 |
| High Frequency Row 11 — Min. PSACRF (PSELFEXT) [DB] | 18.8 |
| High Frequency Row 12 — Min. PSACRF (PSELFEXT) [DB] | 16.8 |
| High Frequency Row 13 — Min. PSACRF (PSELFEXT) [DB] | 15.3 |
| High Frequency Row 14 — Min. PSACRF (PSELFEXT) [DB] | 13.9 |
| High Frequency Row 15 — Min. PSACRF (PSELFEXT) [DB] | 12.8 |
| High Frequency Row 16 — Min. PSACRF (PSELFEXT) [DB] | 11.7 |
| High Frequency Row 17 — Min. PSACRF (PSELFEXT) [DB] | 10.8 |
| High Frequency Row 1 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 2 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 3 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 4 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 5 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 6 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 7 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 8 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 9 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 10 — Max./Min. Fitted Impedance [Ohm] | 105 ± 10 |
| High Frequency Row 11 — Max./Min. Fitted Impedance [Ohm] | 100 ± 10 |
| High Frequency Row 12 — Max./Min. Fitted Impedance [Ohm] | 100 ± 10 |
| High Frequency Row 13 — Max./Min. Fitted Impedance [Ohm] | 100 ± 10 |
| High Frequency Row 14 — Max./Min. Fitted Impedance [Ohm] | 100 ± 10 |
| High Frequency Row 15 — Max./Min. Fitted Impedance [Ohm] | 100 ± 10 |
| High Frequency Row 16 — Max./Min. Fitted Impedance [Ohm] | 100 ± 10 |
| High Frequency Row 17 — Max./Min. Fitted Impedance [Ohm] | 100 ± 10 |
| High Frequency Row 1 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 2 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 3 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 4 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 5 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 6 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 7 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 8 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 9 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) [DB/100m] | 2.1 |
| High Frequency Row 10 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 11 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 22 |
| High Frequency Row 12 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 32 |
| High Frequency Row 13 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 32 |
| High Frequency Row 14 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 32 |
| High Frequency Row 15 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 32 |
| High Frequency Row 16 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 32 |
| High Frequency Row 17 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 32 |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) [DB/100m] | 3.8 |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) [DB/100m] | 5.3 |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) [DB/100m] | 5.9 |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) [DB/100m] | 7.5 |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) [DB/100m] | 8.4 |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) [DB/100m] | 9.4 |
| High Frequency Row 8 — Max. Insertion Loss (Attenuation) [DB/100m] | 10.5 |
| High Frequency Row 9 — Max. Insertion Loss (Attenuation) [DB/100m] | 15.0 |
| High Frequency Row 10 — Max. Insertion Loss (Attenuation) [DB/100m] | 19.1 |
| High Frequency Row 11 — Max. Insertion Loss (Attenuation) [DB/100m] | 27.6 |
| High Frequency Row 12 — Max. Insertion Loss (Attenuation) [DB/100m] | 31.1 |
| High Frequency Row 13 — Max. Insertion Loss (Attenuation) [DB/100m] | 34.3 |
| High Frequency Row 14 — Max. Insertion Loss (Attenuation) [DB/100m] | 37.2 |
| High Frequency Row 15 — Max. Insertion Loss (Attenuation) [DB/100m] | 40.1 |
| High Frequency Row 16 — Max. Insertion Loss (Attenuation) [DB/100m] | 42.7 |
| High Frequency Row 17 — Max. Insertion Loss (Attenuation) [DB/100m] | 45.3 |
Mechanical Characteristics
| Bulk Cable Weight | 34 lbs/1000ft (51 kg/km) |
| Max. Pull Tension | 25 lbs (11 kg) |
| Temperature — Storage | -20°C To +75°C |
| Temperature — Operating | -20°C To +75°C |
| Temperature — Installation | 0°C To +50°C |
| Temperature — UL Temperature | 105°C |
| Bend Radius — Stationary Min. | 1 in (25 mm) |